|
n_TOF Collaboration(Amaducci, S. et al), Domingo-Pardo, C., & Tain, J. L. (2019). Measurement of the U-235(n, f) cross section relative to the Li-6(n, t) and B-10(n,alpha) standards from thermal to 170 keV neutron energy range at n_TOF. Eur. Phys. J. A, 55(7), 120–19pp.
Abstract: .The U-235(n, f ) cross section was measured at n_TOF relative to Li-6(n, t) and B-10(n,alpha) , with high resolution ( L=183.49(2) m) and in a wide energy range (25meV-170keV) with 1.5% systematic uncertainty, making use of a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the yields of the U-235(n, f ) and of the two reference reactions under the same experimental conditions, and taking into account the forward/backward emission asymmetry. A hint of an anomaly in the 10-30keV neutron energy range had been previously observed in other experiments, indicating a cross section systematically lower by several percent relative to major evaluations. The present results indicate that the cross section in the 9-18keV neutron energy range is indeed overestimated by almost 5% in the recently released evaluated data files ENDF/B-VIII.0 and JEFF3.3, as a consequence of a 7% overestimate in a single GMA node in the IAEA reference file. Furthermore, these new high-resolution data confirm the existence of resonance-like structures in the keV neutron energy region. The results here reported may lead to a reduction of the uncertainty in the 1-100keV neutron energy region. Finally, from the present data, a value of 249.7 +/- 1.4( stat )+/- 0.94( syst ) b<bold>eV has been extracted for the cross section integral between </bold>7.8 and 11eV, confirming the value of 247.5 +/- 3 b<bold>eV recently established as a standard</bold>.
|
|
|
Testov, D. et al, & Gadea, A. (2019). The 4pi highly-efficient light-charged-particle detector EUCLIDES, installed at the GALILEO array for in-beam gamma-ray spectroscopy. Eur. Phys. J. A, 55(4), 47–8pp.
Abstract: .In a fusion-evaporation reaction, nuclei are produced by evaporating light-charged particles and neutrons from the compound nucleus. Typically, a nucleus of interest is produced as a result of a part of the total cross-section and, in order to guarantee a good channel discrimination, a particle detector, like the EUCLIDES 4 Si-ball array, is necessary. EUCLIDES has been quoted in more than a hundred publications resulting from many experiments performed in combination with the EUROBALL and GASP -ray spectrometers. The present paper reports on the upgraded version of EUCLIDES, that is presently coupled to the new GALILEO -ray spectrometer, installed at the Laboratori Nazionali di Legnaro, INFN. The design, characteristics and performance of the EUCLIDES array are presented and discussed.
|
|