ATLAS Collaboration(Aad, G. et al), Alvarez Piqueras, D., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fernandez Martinez, P., et al. (2015). Measurement of the top quark mass in the t(t)over-bar -> lepton plus jets and t(t)over-bar -> dilepton channels using root s=7 TeV ATLAS data. Eur. Phys. J. C, 75(7), 330–36pp.
Abstract: The top quark mass was measured in the channels t (t) over bar -> lepton+jets and t (t) over bar -> dilepton (lepton = e, mu) based on ATLAS data recorded in 2011. The data were taken at the LHC with a proton-proton centre-of-mass energy of root s = 7 TeV and correspond to an integrated luminosity of 4.6 fb(-1). The t (t) over bar -> lepton+jets analysis uses a three-dimensional template technique which determines the top quark mass together with a global jet energy scale factor (JSF), and a relative b-to-light-jet energy scale factor (bJSF), where the terms b-jets and light-jets refer to jets originating from b-quarks and u,d,c, s-quarks or gluons, respectively. The analysis of the t (t) over bar -> dilepton channel exploits a one-dimensional template method using the m(lb) observable, defined as the average invariant mass of the two lepton+b-jet pairs in each event. The top quark mass is measured to be 172.33 +/- 0.75(stat + JSF + bJSF) +/- 1.02(syst) GeV, and 173.79 +/- 0.54(stat) +/- 1.30(syst) GeV in the t (t) over bar -> lepton+jets and t (t) over bar -> dilepton channels, respectively. The combination of the two results yields m(top) = 172.99 +/- 0.48(stat) +/- 0.78(syst) GeV, with a total uncertainty of 0.91 GeV.
|
ATLAS Collaboration(Aaboud, M. et al), Alvarez Piqueras, D., Aparisi Pozo, J. A., Bailey, A. J., Barranco Navarro, L., Cabrera Urban, S., et al. (2019). Measurement of the top quark mass in the t(t)over-bar -> lepton plus jets channel from root s=8 TeV ATLAS data and combination with previous results. Eur. Phys. J. C, 79(4), 290–51pp.
Abstract: The top quark mass is measured using a template method in the ttlepton+jets channel (lepton is e or ) using ATLAS data recorded in 2012 at the LHC. The data were taken at a proton-proton centre-of-mass energy of =8 TeV and correspond to an integrated luminosity of 20.2 fb-1. The ttlepton+jets channel is characterized by the presence of a charged lepton, a neutrino and four jets, two of which originate from bottom quarks(b). Exploiting a three-dimensional template technique, the top quark mass is determined together with a global jet energy scale factor and a relative b-to-light-jet energy scale factor. The mass of the top quark is measured to be mtop=172.08 (syst)GeV. A combination with previous ATLAS mtop measurements gives mtop=172.69 +/- 0.25 0.41 (syst) GeV.
|
ATLAS Collaboration(Aaboud, M. et al), Alvarez Piqueras, D., Barranco Navarro, L., Cabrera Urban, S., Castillo Gimenez, V., Cerda Alberich, L., et al. (2016). Measurement of the top quark mass in the t(t)over-bar -> dilepton channel from root s=8 TeV ATLAS data. Phys. Lett. B, 761, 350–371.
Abstract: The top quark mass is measured in the t (t) over bar -> dilepton channel (lepton= e, mu) using ATLAS data recorded in the year 2012 at the LHC. The data were taken at a proton-proton centre-of-mass energy of root s = 8 TeV and correspond to an integrated luminosity of about 20.2 fb(-1). Exploiting the template method, and using the distribution of invariant masses of lepton-b-jetpairs, the top quark mass is measured to be m(top) = 172.99 +/- 0.41(stat)+/- 0.74(syst) GeV, with a total uncertainty of 0.84 GeV. Finally, acombination with previous ATLAS m(top) measurements from root s = 7 TeV data in the t (t) over bar -> dilepton and t (t) over bar -> lepton + jets channels results in m(top) = 172.84 +/- 0.34(stat)+/- 0.61(syst) GeV, with a total uncertainty of 0.70 GeV.
|
ATLAS Collaboration(Aad, G. et al), Amoros, G., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Ferrer, A., et al. (2012). Measurement of the top quark mass with the template method in the t(t)over-bar -> lepton plus jets channel using ATLAS data. Eur. Phys. J. C, 72(6), 2046–30pp.
Abstract: The top quark mass has been measured using the template method in the t (t) over bar -> lepton + jets channel based on data recorded in 2011 with the ATLAS detector at the LHC. The data were taken at a proton-proton centre-of-mass energy of root s = 7 TeV and correspond to an integrated luminosity of 1.04 fb(-1). The analyses in the e + jets and μ+ jets decay channels yield consistent results. The top quark mass is measured to be m(top) = 174.5 +/- 0.6(stat) +/- 2.3(syst) GeV.
|
ATLAS Collaboration(Aad, G. et al), Aparisi Pozo, J. A., Bailey, A. J., Cabrera Urban, S., Castillo, F. L., Castillo Gimenez, V., et al. (2020). Measurement of the t(t)over-bar production cross-section in the lepton plus jets channel at root s=13 TeV with the ATLAS experiment. Phys. Lett. B, 810, 135797–22pp.
Abstract: The top anti-top quark production cross-section is measured in the lepton+jets channel using proton-proton collision data at a centre-of-mass energy of root s = 13 TeV collected with the ATLAS detector at the LHC. The dataset corresponds to an integrated luminosity of 139 fb(-1). Events with exactly one charged lepton and four or more jets in the final state, with at least one jet containing b-hadrons, are used to determine the a production cross-section through a profile-likelihood t (t) over bar. The inclusive cross-section is measured to be alpha(inc) = 830 +/- 0.4 (stat.) +/- 36 (syst.) +/- 14 (lumi.) pb with a relative uncertainty of 4.6%. The result is consistent with theoretical calculations at next-to-next-to-leading order in perturbative QCD. The fiducial t (t) over bar cross-section within the experimental acceptance is also measured.
|
ATLAS Collaboration(Aad, G. et al), Amoros, G., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Escobar, C., et al. (2010). Readiness of the ATLAS Tile Calorimeter for LHC collisions. Eur. Phys. J. C, 70(4), 1193–1236.
Abstract: The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the detector has successfully collected data from the LHC single beams in 2008 and first collisions in 2009. This paper gives an overview of the Tile Calorimeter performance as measured using random triggers, calibration data, data from cosmic ray muons and single beam data. The detector operation status, noise characteristics and performance of the calibration systems are presented, as well as the validation of the timing and energy calibration carried out with minimum ionising cosmic ray muons data. The calibration systems' precision is well below the design value of 1%. The determination of the global energy scale was performed with an uncertainty of 4%.
|
ATLAS Tile Calorimeter Community(Abdallah, J. et al), Castillo Gimenez, V., Costelo, J., Ferrer, A., Fullana, E., Gonzalez, V., et al. (2013). The optical instrumentation of the ATLAS Tile Calorimeter. J. Instrum., 8, P01005–21pp.
Abstract: The Tile Calorimeter, covering the central region of the ATLAS experiment up to pseudorapidities of +/-1.7, is a sampling device built with scintillating tiles that alternate with iron plates. The light is collected in wave-length shifting (WLS) fibers and is read out with photomultipliers. In the characteristic geometry of this calorimeter the tiles lie in planes perpendicular to the beams, resulting in a very simple and modular mechanical and optical layout. This paper focuses on the procedures applied in the optical instrumentation of the calorimeter, which involved the assembly of about 460,000 scintillator tiles and 550,000 WLS fibers. The outcome is a hadronic calorimeter that meets the ATLAS performance requirements, as shown in this paper.
|
ATLAS Collaboration(Aaboud, M. et al), Alvarez Piqueras, D., Bailey, A. J., Barranco Navarro, L., Cabrera Urban, S., Carrio Argos, F., et al. (2018). Operation and performance of the ATLAS Tile Calorimeter in Run 1. Eur. Phys. J. C, 78(12), 987–48pp.
Abstract: The Tile Calorimeter is the hadron calorimeter covering the central region of the ATLAS experiment at the Large Hadron Collider. Approximately 10,000 photomultipliers collect light from scintillating tiles acting as the active material sandwiched between slabs of steel absorber. This paper gives an overview of the calorimeter's performance during the years 2008-2012 using cosmic-ray muon events and proton-proton collision data at centre-of-mass energies of 7 and 8 TeV with a total integrated luminosity of nearly 30 fb(-1). The signal reconstruction methods, calibration systems as well as the detector operation status are presented. The energy and time calibration methods performed excellently, resulting in good stability of the calorimeter response under varying conditions during the LHC Run 1. Finally, the Tile Calorimeter response to isolated muons and hadrons as well as to jets from proton-proton collisions is presented. The results demonstrate excellent performance in accord with specifications mentioned in the Technical Design Report.
|
ATLAS Collaboration(Aad, G. et al), Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fassi, F., Ferrer, A., et al. (2015). Measurement of the t(t)over-bar production cross-section as a function of jet multiplicity and jet transverse momentum in 7 TeV proton-proton collisions with the ATLAS detector. J. High Energy Phys., 01(1), 020–67pp.
Abstract: The t (t) over bar production cross-section dependence on jet multiplicity and jet transverse momentum is reported for proton-proton collisions at a centre-of-mass energy of 7 TeV in the single-lepton channel. The data were collected with the ATLAS detector at the CERN Large Hadron Collider and comprise the full 2011 data sample corresponding to an integrated luminosity of 4.6 fb(-1). Differential cross-sections are presented as a function of the jet multiplicity for up to eight jets using jet transverse momentum thresholds of 25, 40, 60, and 80 GeV, and as a function of jet transverse momentum up to the fifth jet. The results are shown after background subtraction and corrections for all known detector effects, within a kinematic range closely matched to the experimental acceptance. Several QCD-based Monte Carlo models are compared with the results. Sensitivity to the parton shower modelling is found at the higher jet multiplicities, at high transverse momentum of the leading jet and in the transverse momentum spectrum of the fifth leading jet. The MC@NLO+HERWIG MC is found to predict too few events at higher jet multiplicities.
|
ATLAS Collaboration(Aad, G. et al), Alvarez Piqueras, D., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fernandez Martinez, P., et al. (2016). Constraints on non-Standard Model Higgs boson interactions in an effective Lagrangian using differential cross sections measured in the H ->gamma gamma decay channel at root s=8 TeV with the ATLAS detector. Phys. Lett. B, 753, 69–85.
Abstract: The strength and tensor structure of the Higgs boson's interactions are investigated using an effective Lagrangian, which introduces additional CP-even and CP-odd interactions that lead to changes in the kinematic properties of the Higgs boson and associated jet spectra with respect to the Standard Model. The parameters of the effective Lagrangian are probed using a fit to five differential cross sections previously measured by the ATLAS experiment in the H ->gamma gamma decay channel with an integrated luminosity of 20.3 fb(-1) at root s= 8 TeV. Inorder to perform a simultaneous fit to the five distributions, the statistical correlations between them are determined by re-analysing the H ->gamma gamma candidate events in the proton-proton collision data. No significant deviations from the Standard Model predictions are observed and limits on the effective Lagrangian parameters are derived. The statistical correlations are made publicly available to allow for future analysis of theories with non-Standard Model interactions.
|