T2K Collaboration(Abe, K. et al), Cervera-Villanueva, A., Izmaylov, A., Novella, P., & Sorel, M. (2017). Combined Analysis of Neutrino and Antineutrino Oscillations at T2K. Phys. Rev. Lett., 118(15), 151801–9pp.
Abstract: T2K reports its first results in the search for CP violation in neutrino oscillations using appearance and disappearance channels for neutrino-and antineutrino-mode beams. The data include all runs from January 2010 to May 2016 and comprise 7.482 x 10(20) protons on target in neutrino mode, which yielded in the far detector 32 e-like and 135 mu-like events, and 7.471 x 10(20) protons on target in antineutrino mode, which yielded 4 e-like and 66 mu-like events. Reactor measurements of sin(2) 2 theta(13) have been used as an additional constraint. The one-dimensional confidence interval at 90% for the phase delta(CP) spans the range (-3.13,-0.39) for normal mass ordering. The CP conservation hypothesis (delta(CP) = 0, pi) is excluded at 90% C.L.
|
Chatterjee, S. S., Pasquini, P., & Valle, J. W. F. (2017). Resolving the atmospheric octant by an improved measurement of the reactor angle. Phys. Rev. D, 96(1), 011303–6pp.
Abstract: Taking into account the current global information on neutrino oscillation parameters we forecast the capabilities of future long-baseline experiments such as DUNE and T2HK in settling the atmospheric octant puzzle. We find that a good measurement of the reactor angle theta(13) plays a key role in fixing the octant of the atmospheric angle theta(23) with such future accelerator neutrino studies.
|
NEXT Collaboration(Cebrian, S. et al), Perez, J., Alvarez, V., Benlloch-Rodriguez, J., Botas, A., Carcel, S., et al. (2017). Radiopurity assessment of the energy readout for the NEXT double beta decay experiment. J. Instrum., 12, T08003–20pp.
Abstract: The “Neutrino Experiment with a Xenon Time-Projection Chamber” (NEXT) experiment intends to investigate the neutrinoless double beta decay of Xe-136, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 x 10(-4) counts keV(-1) kg(-1) y(-1), satisfying the sensitivity requirements of the NEXT experiment.
|
Gimenez-Alventosa, V., Antunes, P. C. G., Vijande, J., Ballester, F., Perez-Calatayud, J., & Andreo, P. (2017). Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy. Phys. Med. Biol., 62(1), 146–164.
Abstract: The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seeds is proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences. State-of-the art Monte Carlo calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone), which in all cases include a realistic modelling of low-energy brachytherapy sources in order to benchmark the formalism proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases (e.g. bone tissue).
|
Garcia, A. R., Mendoza, E., Cano-Ott, D., Nolte, R., Martinez, T., Algora, A., et al. (2017). New physics model in GEANT4 for the simulation of neutron interactions with organic scintillation detectors. Nucl. Instrum. Methods Phys. Res. A, 868, 73–81.
Abstract: The accurate determination of the response function of organic scintillation neutron detectors complements their experimental characterization. Monte Carlo simulations with GEANT4 can reduce the effort and cost implied, especially for complex detection systems for which the characterization is more challenging. Previous studies have reported on the inaccuracy of GEANT4 in the calculation of the neutron response of organic scintillation detectors above 6 MeV, due to an incomplete description of the neutron-induced alpha production reactions on carbon. We have improved GEANT4 in this direction by incorporating models and data from NRESP, an excellent Monte Carlo simulation tool developed at the Physikalisch-Technische Bundesanstalt (PTB), Germany, for the specific purpose of calculating the neutron response function of organic scintillation detectors. The results have been verified against simulations with NRESP and validated against Time-Of-Flight measurements with an NE213 detector at PTB. This work has potential applications beyond organic scintillation detectors, to other types of detectors where reactions induced by fast neutrons on carbon require an accurate description.
|