Gonzalez-Iglesias, D., Aksoy, A., Esperante, D., Gimeno, B., Latina, A., Boronat, M., et al. (2021). X-band RF photoinjector design for the CompactLight project. Nucl. Instrum. Methods Phys. Res. A, 1014, 165709–10pp.
Abstract: RF photoinjectors have been under development for several decades to provide the high-brightness electron beams required for X-ray Free Electron Lasers. This paper proposes a photoinjector design that meets the Horizon 2020 CompactLight design study requirements. It consists of a 5.6-cell, X-band (12 GHz) RF gun, an emittance-compensating solenoid and two X-band traveling-wave structures that accelerate the beam out of the space-charge-dominated regime. The RF gun is intended to operate with a cathode gradient of 200 MV/m, and the TW structures at a gradient of 65 MV/m. The shape of the gun cavity cells was optimized to reduce the peak electric surface field. An assessment of the gun RF breakdown likelihood is presented as is a multipacting analysis for the gun coaxial coupler. RF pulse heating on the gun inner surfaces is also evaluated and beam dynamics simulations of the 100 MeV photoinjector are summarized.
|
|
|
Calatayud-Jordan, J., Candela-Juan, C., Palma, J. D., Pujades-Claumarchirant, M. C., Soriano, A., Gracia-Ochoa, M., et al. (2021). Influence of the simultaneous calibration of multiple ring dosimeters on the individual absorbed dose. J. Radiol. Prot., 41(2), 384–397.
Abstract: Ring dosimeters for personal dosimetry are calibrated in accredited laboratories following ISO 4037-3 guidelines. The simultaneous irradiation of multiple dosimeters would save time, but has to be carefully studied, since the scattering conditions could change and influence the absorbed dose in nearby dosimeters. Monte Carlo simulations using PENELOPE-2014 were performed to explore the need to increase the uncertainty of H-p (0.07) in the simultaneous irradiation of three and five DXT-RAD 707H-2 (Thermo Scientific) ring dosimeters with beam qualities: N-30, N-80 and N-300. Results show that the absorbed dose in each dosimeter is compatible with each of the others and with the reference simulation (a single dosimeter), with a coverage probability of 95% (k = 2). Comparison with experimental data yielded consistent results with the same coverage probability. Therefore, five ring dosimeters can be simultaneously irradiated with beam qualities ranging, at least, between N-30 and N-300 with a negligible impact on the uncertainty of H-p (0.07).
|
|
|
LHCb Collaboration(Aaij, R. et al), Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2021). Search for CP violation in D-(s)(+) -> h(+) pi(0) and decays D-(s)(+) -> h(+) eta decays. J. High Energy Phys., 06(6), 019–25pp.
Abstract: Searches for CP violation in the two-body decays D-(s)(+) -> h(+)pi(0) and D-(s)(+) -> h(+)eta (where h(+) denotes a pi(+) or K+ meson) are performed using pp collision data collected by the LHCb experiment corresponding to either 9 fb(-1) or 6 fb(-1) of integrated luminosity. The pi(0) and eta mesons are reconstructed using the e(+) e(-)gamma final state, which can proceed as three-body decays pi(0) -> e(+) e(-) gamma and eta -> e(+) e(-)gamma, or via the two-body decays pi(0) -> gamma gamma and eta -> gamma gamma followed by a photon conversion. The measurements are made relative to the control modes D-(s)(+) K(S)(0)h(+) to cancel the production and detection asymmetries. The CP asymmetries are measured to be A(CP)(D+ -> pi(+)pi(0)) = (-1.3 +/- 0.9 +/- 0.6)%, A(CP)(D+ -> K+pi(0)) = (- 3.2 +/- 4.7 +/- 2.1)%, A(CP)(D+ -> pi(+)eta) = (-0.2 +/- 0.8 +/- 0.4)%, A(CP)(D+ -> K+eta) = (-6 +/- 10 +/- 4 )%, A(CP)(D-s(+) -> K+pi(0)) = (-0.8 +/- 3.9 +/- 1.2)%, A(CP)(D-s(+) -> pi(+)eta) = ( 0.8 +/- 0.7 +/- 0.5)%, A(CP)(D-s(+) -> K+eta) = ( 0.9 +/- 3.7 +/- 1.1)%, where the first uncertainties are statistical and the second systematic. These results are consistent with no CP violation and mostly constitute the most precise measurements of A(CP) in these decay modes to date.
|
|
|
ATLAS Collaboration(Aad, G. et al), Aparisi Pozo, J. A., Bailey, A. J., Cabrera Urban, S., Cardillo, F., Castillo, F. L., et al. (2021). Search for resonances decaying into photon pairs in 139 fb(-1) of pp collisions at root s=13 TeV with the ATLAS detector. Phys. Lett. B, 822, 136651–19pp.
Abstract: Searches for new resonances in the diphoton final state, with spin 0 as predicted by theories with an extended Higgs sector and with spin 2 using a warped extra-dimension benchmark model, are presented using 139 fb(-1) of root s = 13 TeV pp collision data collected by the ATLAS experiment at the LHC. No significant deviation from the Standard Model is observed and upper limits are placed on the production cross-section times branching ratio to two photons as a function of the resonance mass.
|
|
|
ATLAS Collaboration(Aad, G. et al), Aparisi Pozo, J. A., Bailey, A. J., Cabrera Urban, S., Cardillo, F., Castillo, F. L., et al. (2021). Search for Dark Matter Produced in Association with a Dark Higgs Boson Decaying into (WW -/+)-W-+/- or ZZ in Fully Hadronic Final States from root s=13 TeV pp Collisions Recorded with the ATLAS Detector. Phys. Rev. Lett., 126(12), 121802–21pp.
Abstract: Several extensions of the Standard Model predict the production of dark matter particles at the LHC. An uncharted signature of dark matter particles produced in association with VV = (WW -/+)-W-+/- or ZZ pairs from a decay of a dark Higgs boson s is searched for using 139 fb(-1) of pp collisions recorded by the ATLAS detector at a center-of-mass energy of 13 TeV. The s -> V(q (q) over bar )V(q (q) over bar) decays are reconstructed with a novel technique aimed at resolving the dense topology from boosted VV pairs using jets in the calorimeter and tracking information. Dark Higgs scenarios with m(s) > 160 GeV are excluded.
|
|