Gonzalez, P., Mathieu, V., & Vento, V. (2011). Heavy meson interquark potential. Phys. Rev. D, 84(11), 114008–7pp.
Abstract: The resolution of Dyson-Schwinger equations leads to the freezing of the QCD running coupling (effective charge) in the infrared, which is best understood as a dynamical generation of a gluon mass function, giving rise to a momentum dependence which is free from infrared divergences. We calculate the interquark static potential for heavy mesons by assuming that it is given by a massive One Gluon Exchange interaction and compare with phenomenologyical fits inspired by lattice QCD. We apply these potential forms to the description of quarkonia and conclude that, even though some aspects of the confinement mechanism are absent in the Dyson-Schwinger formalism, the spectrum can be reasonably reproduced. We discuss possible explanations for this outcome.
|
|
|
ATLAS Collaboration(Abat, E. et al), Bernabeu Verdu, J., Castillo Gimenez, V., Costa, M. J., Escobar, C., Ferrer, A., et al. (2011). Photon reconstruction in the ATLAS Inner Detector and Liquid Argon Barrel Calorimeter at the 2004 Combined Test Beam. J. Instrum., 6, P04001–40pp.
Abstract: The reconstruction of photons in the ATLAS detector is studied with data taken during the 2004 Combined Test Beam, where a full slice of the ATLAS detector was exposed to beams of particles of known energy at the CERN SPS. The results presented show significant differences in the longitudinal development of the electromagnetic shower between converted and unconverted photons as well as in the total measured energy. The potential to use the reconstructed converted photons as a means to precisely map the material of the tracker in front of the electromagnetic calorimeter is also considered. All results obtained are compared with a detailed Monte-Carlo simulation of the test-beam setup which is based on the same simulation and reconstruction tools as those used for the ATLAS detector itself.
|
|
|
n_TOF Collaboration(Belloni, F. et al), Domingo-Pardo, C., & Tain, J. L. (2011). Measurement of the neutron-induced fission cross-section of Am-243 relative to U-235 from 0.5 to 20 MeV. Eur. Phys. J. A, 47(12), 160–8pp.
Abstract: The ratio of the neutron-induced fission cross-sections of Am-243 and U-235 was measured in the energy range from 0.5 to 20 MeV with uncertainties of approximate to 4%. The experiment was performed at the CERN n_TOF facility using a fast ionization chamber. With the good counting statistics that could be achieved thanks to the high instantaneous flux and the low backgrounds, the present results are useful for resolving discrepancies in previous data sets and are important for future reactors with improved fuel burn-up.
|
|
|
Borexino Collaboration(Bellini, G. et al), & Pena-Garay, C. (2011). Precision Measurement of the (7)Be Solar Neutrino Interaction Rate in Borexino. Phys. Rev. Lett., 107(14), 141302–5pp.
Abstract: The rate of neutrino-electron elastic scattering interactions from 862 keV (7)Be solar neutrinos in Borexino is determined to be 46.0 +/- 1.5(stat)(-1.6)(+1.5)(syst)counts/(day . 100 ton). This corresponds to a nu(e)-equivalent (7)Be solar neutrino flux of (3.10 +/- 0.15) x 10(9) cm(-2) s(-1) and, under the assumption of nu(e) transition to other active neutrino flavours, yields an electron neutrino survival probability of 0.51 +/- 0.07 at 862 keV. The no flavor change hypothesis is ruled out at 5.0 sigma. A global solar neutrino analysis with free fluxes determines Phi(pp) = 6.06(-0.66)(+0.02) x 10(10) cm(-2) s(-1) and Phi(CNO) < 1.3 x 10(9) cm(-2) s(-1) (95% C.L.). These results significantly improve the precision with which the Mikheyev-Smirnov-Wolfenstein large mixing angle neutrino oscillation model is experimentally tested at low energy.
|
|
|
Morales, A. I. et al, Agramunt, J., Algora, A., Gadea, A., Molina, F., & Rubio, B. (2011). Synthesis of N=127 isotones through (p,n) charge-exchange reactions induced by relativistic (208)Pb projectiles. Phys. Rev. C, 84(1), 011601–5pp.
Abstract: The production cross sections of four N = 127 isotones ((207)Hg, (206)Au, (205)Pt, and (204)Ir) have been measured using (p,n) charge-exchange reactions, induced in collisions of a (208)Pb primary beam at 1 A GeV with a Be target. These data allow one to investigate the use of a reaction mechanism to extend the limits of the chart of nuclides toward the important r-process nuclei in the region of the third peak of elemental abundance distribution.
|
|
|
Nguyen, C. V., Gillam, J. E., Brown, J. M. C., Martin, D. V., Nikulin, D. A., & Dimmock, M. R. (2011). Towards Optimal Collimator Design for the PEDRO Hybrid Imaging System. IEEE Trans. Nucl. Sci., 58(3), 639–650.
Abstract: The Pixelated Emission Detector for RadiOisotopes (PEDRO) is a hybrid imaging system designed for the measurement of single photon emission from small animal models. The proof-of-principle device consists of a Compton-camera situated behind a mechanical collimator and is intended to provide optimal detection characteristics over a broad spectral range, from 30 to 511 keV. An automated routine has been developed for the optimization of large-area slits in the outer regions of a collimator which has a central region allocated for pinholes. The optimization was tested with a GEANT4 model of the experimental prototype. The data were blurred with the expected position and energy resolution parameters and a Bayesian interaction ordering algorithm was applied. Images were reconstructed using cone back-projection. The results show that the optimization technique allows the large-area slits to both sample fully and extend the primary field of view (FoV) determined by the pinholes. The slits were found to provide truncation of the back-projected cones of response and also an increase in the success rate of the interaction ordering algorithm. These factors resulted in an increase in the contrast and signal-to-noise ratio of the reconstructed image estimates. Of the two configurations tested, the cylindrical geometry outperformed the square geometry, primarily because of a decrease in artifacts. This was due to isotropic modulation of the cone surfaces, that can be achieved with a circular shape. Also, the cylindrical geometry provided increased sampling of the FoV due to more optimal positioning of the slits. The use of the cylindrical collimator and application of the transmission function in the reconstruction was found to improve the resolution of the system by a factor of 20, as compared to the uncollimated Compton camera. Although this system is designed for small animal imaging, the technique can be applied to any application of single photon imaging.
|
|
|
Pierre Auger Collaboration(Abreu, P. et al), & Pastor, S. (2011). The exposure of the hybrid detector of the Pierre Auger Observatory. Astropart Phys., 34(6), 368–381.
Abstract: The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The “hybrid” detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction.
|
|
|
Pierre Auger Collaboration(Abreu, P. et al), & Pastor, S. (2011). Anisotropy and chemical composition of ultra-high energy cosmic rays using arrival directions measured by the Pierre Auger Observatory. J. Cosmol. Astropart. Phys., 06(6), 022–17pp.
Abstract: The Pierre Auger Collaboration has reported. evidence for anisotropy in the distribution of arrival directions of the cosmic rays with energies E > E-th = 5.5 x 10(19) eV. These show a correlation with the distribution of nearby extragalactic objects, including an apparent excess around the direction of Centaurus A. If the particles responsible for these excesses at E > E-th are heavy nuclei with charge Z, the proton component of the sources should lead to excesses in the same regions at energies E/Z. We here report the lack of anisotropies in these directions at energies above E-th/Z (for illustrative values of Z = 6, 13, 26). If the anisotropies above E-th are due to nuclei with charge Z, and under reasonable assumptions about the acceleration process, these observations imply stringent constraints on the allowed proton fraction at the lower energies.
|
|
|
Semikoz, V. B., & Valle, J. W. F. (2011). Chern-Simons anomaly as polarization effect. J. Cosmol. Astropart. Phys., 11(11), 048.
Abstract: The parity violating, Chern-Simons term in the epoch before the electroweak phase transition can be interpreted as a polarization effect associated to massless right-handed electrons (positrons) in the presence of a large-scale seed hypermagnetic field. We reconfirm the viability of a unified seed field scenario relating the cosmological baryon asymmetry and the origin of the protogalactic large-scale magnetic fields observed in astronomy.
|
|
|
Andricek, L. et al, Lacasta, C., Marinas, C., & Vos, M. (2011). Intrinsic resolutions of DEPFET detector prototypes measured at beam tests. Nucl. Instrum. Methods Phys. Res. A, 638(1), 24–32.
Abstract: The paper is based on the data of the 2009 DEPFET beam test at CERN SPS. The beam test used beams of pions and electrons with energies between 40 and 120 GeV, and the sensors tested were prototypes with thickness of 450 μm and pixel pitch between 20 and 32 μm. Intrinsic resolutions of the detectors are calculated by disentangling the contributions of measurement errors and multiple scattering in tracking residuals. Properties of the intrinsic resolution estimates and factors that influence them are discussed. For the DEPFET detectors in the beam test, the calculation yields intrinsic resolutions of approximate to 1 μm, with a typical accuracy of 0.1 μm. Bias scan, angle scan, and energy scan are used as example studies to show that the intrinsic resolutions are a useful tool in studies of detector properties. With sufficiently precise telescopes, detailed resolution maps can be constructed and used to study and optimize detector performance.
|
|