|
Soderstrom, P. A. et al, Algora, A., & Gadea, A. (2010). Spectroscopy of neutron-rich Dy-168,Dy-170: Yrast band evolution close to the NpNn valence maximum. Phys. Rev. C, 81(3), 034310–5pp.
Abstract: The yrast sequence of the neutron-rich dysprosium isotope Dy-168 has been studied using multinucleon transfer reactions following collisions between a 460-MeV Se-82 beam and an Er-170 target. The reaction products were identified using the PRISMA magnetic spectrometer and the gamma rays detected using the CLARA HPGe-detector array. The 2(+) and 4(+) members of the previously measured ground-state rotational band of Dy-168 have been confirmed and the yrast band extended up to 10(+). A tentative candidate for the 4(+) -> 2(+) transition in Dy-170 was also identified. The data on these nuclei and on the lighter even-even dysprosium isotopes are interpreted in terms of total Routhian surface calculations and the evolution of collectivity in the vicinity of the proton-neutron valence product maximum is discussed.
|
|
|
Pasqualato, G. et al, Domingo-Pardo, C., & Gadea, A. (2023). Shape evolution in even-mass 98-104Zr isotopes via lifetime measurements using the γ γ-coincidence technique. Eur. Phys. J. A, 59(11), 276–13pp.
Abstract: The Zirconium (Z = 40) isotopic chain has attracted interest for more than four decades. The abrupt lowering of the energy of the first 2(+) state and the increase in the transition strength B(E2; 2(1)(+) -> 0(1)(+) ) going from Zr-98 to Zr-100 has been the first example of “quantum phase transition” in nuclear shapes, which has few equivalents in the nuclear chart. Although a multitude of experiments have been performed to measure nuclear properties related to nuclear shapes and collectivity in the region, none of the measured lifetimes were obtained using the Recoil Distance Doppler Shift method in the gamma gamma-coincidence mode where a gate on the direct feeding transition of the state of interest allows a strict control of systematical errors. This work reports the results of lifetime measurements for the first yrast excited states in Zr98-104 carried out to extract reduced transition probabilities. The new lifetime values in gamma gamma-coincidence and gamma-single mode are compared with the results of former experiments. Recent predictions of the Interacting Boson Model with Configuration Mixing, the Symmetry Conserving Configuration Mixing model based on the Hartree-Fock- Bogoliubov approach and the Monte Carlo Shell Model are presented and compared with the experimental data.
|
|
|
Montanari, D. et al, & Gadea, A. (2012). Gamma spectroscopy of calcium nuclei around doubly magic Ca-48 using heavy-ion transfer reactions. Phys. Rev. C, 85(4), 044301–21pp.
Abstract: The. decays of neutron-rich Ca isotopes around Ca-48 were measured at Legnaro National Laboratory with the PRISMA-CLARA setup, using the heavy-ion transfer reactions Ca-48 on Ni-64 and Ca-48 on Pb-208 at approximate to 6 MeV/A. The work shows the feasibility to perform full in-beam gamma spectroscopy with heavy-ion transfer reactions (in terms of angular distributions, polarizations, and lifetimes analysis), providing a method that can be further exploited in the future with heavy targets and radioactive beams. For the one-neutron transfer channels, Ca-49 and Ca-47, shell-model and particle-vibration coupling calculations are used to understand the nature of the states. In particular, in both nuclei evidence is found for particle-vibration coupled states based on the 3(-) phonon of Ca-48. In the two-neutron transfer channels, Ca-46 and Ca-50, the experimental data are in global agreement with predictions based on full fp shell-model calculations.
|
|
|
Egea Canet, F. J. et al, Gadea, A., & Huyuk, T. (2015). Digital Front-End Electronics for the Neutron Detector NEDA. IEEE Trans. Nucl. Sci., 62(3), 1063–1069.
Abstract: This paper presents the design of the NEDA (Neutron Detector Array) electronics, a first attempt to involve the use of digital electronics in large neutron detector arrays. Starting from the front-end modules attached to the PMTs (PhotoMultiplier Tubes) and ending up with the data processing workstations, a comprehensive electronic system capable of dealing with the acquisition and pre-processing of the neutron array is detailed. Among the electronic modules required, we emphasize the front-end analog processing, the digitalization, digital pre-processing and communications firmware, as well as the integration of the GTS (Global Trigger and Synchronization) system, already used successfully in AGATA (Advanced Gamma Tracking Array). The NEDA array will be available for measurements in 2016.
|
|
|
Egea Canet, F. J. et al, Gadea, A., & Huyuk, T. (2015). A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors. IEEE Trans. Nucl. Sci., 62(3), 1056–1062.
Abstract: This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
|
|