Agramunt, J. et al, Tain, J. L., Albiol, F., Algora, A., Domingo-Pardo, C., Jordan, M. D., et al. (2016). Characterization of a neutron-beta counting system with beta-delayed neutron emitters. Nucl. Instrum. Methods Phys. Res. A, 807, 69–78.
Abstract: A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known beta-delayed neutron emission properties. The setup consists of BELEN-20, a 4 pi-neutron counter with twenty He-3 proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for beta counting and a self-triggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, beta and beta-neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on the accuracy of neutron emission probabilities is discussed. A new accurate value of the neutron emission probability for the important delayed-neutron precursor I-137 was obtained, P-n = 7.76(14)%.
|
Stuhl, L., Krasznahorkay, A., Csatlos, M., Algora, A., Gulyas, J., Kalinka, G., et al. (2014). A neutron spectrometer for studying giant resonances with (p,n) reactions in inverse kinematics. Nucl. Instrum. Methods Phys. Res. A, 736, 1–9.
Abstract: A neutron spectrometer, the European Low-Energy Neutron Spectrometer (ELENS), has been constructed to study exotic nuclei in inverse-kinematics experiments. The spectrometer, which consists of plastic scintillator bars, can be operated in the neutron energy range of 100 keV-10 MeV. The neutron energy is determined using the time-of-flight technique, while the position of the neutron detection is deduced from the time-difference information from photomultipliers attached to both ends of each bar. A novel wrapping method has been developed for the plastic scintillators. The array has a larger than 25% detection efficiency for neutrons of approximately 500 keV in kinetic energy and an angular resolution of less than 1 degrees. Details of the design, construction and experimental tests of the spectrometer will be presented.
|
Cervera-Villanueva, A., Laing, A., Martin-Albo, J., & Soler, F. J. P. (2010). Performance of the MIND detector at a Neutrino Factory using realistic muon reconstruction. Nucl. Instrum. Methods Phys. Res. A, 624(3), 601–614.
Abstract: A Neutrino Factory producing an intense beam composed of v(e)((v) over bar (e)) and (v) over bar (mu)(v(mu)) from muon decays has been shown to have the greatest sensitivity to the two currently unmeasured neutrino mixing parameters theta(13) and delta(CP) Using the wrong-sign muon signal to measure v(e)-> v(mu)((v) over bar (e) ->(v) over bar (mu)) oscillations in a 50kt Magnetised Iron Neutrino Detector (MIND) sensitivity to delta(CP) could be maintained down to small values of theta(13) However the detector efficiencies used in these previous studies were calculated assuming perfect pattern recognition In this paper MIND is reassessed taking into account for the first time a realistic pattern recognition for the muon candidate Reoptimisation of the analysis utilises a combination of methods including a multivariate analysis similar to the one used in MINOS to maintain high efficiency while suppressing backgrounds ensuring that the signal selection efficiency and the background levels are comparable or better than the ones in previous analyses As a result MIND remains the most sensitive future facility for the discovery of CP violation from neutrino oscillations.
|
Chiera, N. M., Maugeri, E. A., Danilov, I., Balibrea-Correa, J., Domingo-Pardo, C., Koster, U., et al. (2022). Preparation of PbSe targets for Se-79 neutron capture cross section studies. Nucl. Instrum. Methods Phys. Res. A, 1029, 166443–7pp.
Abstract: A methodology for the production of PbSe targets for Se-79 neutron capture cross section studies is presented. PbSe material was synthesized by direct reaction of its constituents at high temperature, and characterized by X-ray diffraction. Thin PbSe targets, produced for cross section experiments with the surrogate reaction method, were obtained by applying a physical vapor deposition technique, and their morphology and composition were analyzed by X-ray fluorescence, Scanning Electron Microscopy, and Energy dispersive X-ray spectroscopy. (PbSe)-Se-79 targets produced for cross section measurements with the Time of Flight method were characterized by gamma-ray spectroscopy. Finally, a procedure for the recovery of Se from PbSe is suggested. The purity of the retrieved Se was determined with Inductively Coupled Plasma Optical Emission Spectroscopy.
|
Mengoni, D., Duenas, J. A., Assie, M., Boiano, C., John, P. R., Aliaga, R. J., et al. (2014). Digital pulse-shape analysis with a TRACE early silicon prototype. Nucl. Instrum. Methods Phys. Res. A, 764, 241–246.
Abstract: A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination.
|