|
Martin-Luna, P., Esperante, D., Prieto, A. F., Fuster-Martinez, N., Rivas, I. G., Gimeno, B., et al. (2024). Simulation of electron transport and secondary emission in a photomultiplier tube and validation. Sens. Actuator A-Phys., 365, 114859–10pp.
Abstract: The electron amplification and transport within a photomultiplier tube (PMT) has been investigated by developing an in-house Monte Carlo simulation code. The secondary electron emission in the dynodes is implemented via an effective electron model and the Modified Vaughan's model, whereas the transport is computed with the Boris leapfrog algorithm. The PMT gain, rise time and transit time have been studied as a function of supply voltage and external magnetostatic field. A good agreement with experimental measurements using a Hamamatsu R13408-100 PMT was obtained. The simulations have been conducted following different treatments of the underlying geometry: three-dimensional, two-dimensional and intermediate (2.5D). The validity of these approaches is compared. The developed framework will help in understanding the behavior of PMTs under highly intense and irregular illumination or varying external magnetic fields, as in the case of prompt gamma-ray measurements during pencil-beam proton therapy; and aid in optimizing the design of voltage dividers with behavioral circuit models.
|
|
|
Navarro, P., Gimeno, B., Monzo-Cabrera, J., Diaz-Morcillo, A., & Blas, D. (2024). Study of a cubic cavity resonator for gravitational waves detection in the microwave frequency range. Phys. Rev. D, 109(10), 104048–19pp.
Abstract: The direct detection of gravitational waves (GWs) of frequencies above MHz has recently received considerable attention. In this work, we present a precise study of the reach of a cubic cavity resonator to GWs in the microwave range, using for the first time tools allowing to perform realistic simulations. Concretely, the boundary integral -resonant mode expansion (BI-RME) 3D method, which allows us to obtain not only the detected power but also the detected voltage (magnitude and phase), is used here. After analyzing three cubic cavities for different frequencies and working simultaneously with three different degenerate modes at each cavity, we conclude that the sensitivity of the experiment is strongly dependent on the polarization and incidence angle of the GW. The presented experiment can reach sensitivities up to 1 x 10 – 19 at 100 MHz, 2 x 10 – 20 at 1 GHz, and 6 x 10 – 19 at 10 GHz for optimal angles and polarizations, and where in all cases we assumed an integration time of Delta t 1 / 4 1 ms. These results provide a strong case for further developing the use of cavities to detect GWs. Moreover, the possibility of analyzing the detected voltage (magnitude and phase) opens a new interferometric detection scheme based on the combination of the detected signals from multiple cavities.
|
|
|
Andreotti, M. et al, Cervera-Villanueva, A., Garcia-Peris, M. a., Martin-Albo, J., Querol, M., Rocabado, J., et al. (2024). Cryogenic characterization of Hamamatsu HWB MPPCs for the DUNE photon detection system. J. Instrum., 19(1), T01007–27pp.
Abstract: The Deep Underground Neutrino Experiment (DUNE) is a next generation experiment aimed to study neutrino oscillation. Its long-baseline configuration will exploit a Near Detector (ND) and a Far Detector (FD) located at a distance of similar to 1300 km. The FD will consist of four Liquid Argon Time Projection Chamber (LAr TPC) modules. A Photon Detection System (PDS) will be used to detect the scintillation light produced inside the detector after neutrino interactions. The PDS will be based on light collectors coupled to Silicon Photomultipliers (SiPMs). Different photosensor technologies have been proposed and produced in order to identify the best samples to fullfill the experiment requirements. In this paper, we present the procedure and results of a validation campaign for the Hole Wire Bonding (HWB) MPPCs samples produced by Hamamatsu Photonics K.K. (HPK) for the DUNE experiment, referring to them as 'SiPMs'. The protocol for a characterization at cryogenic temperature (77 K) is reported. We present the down-selection criteria and the results obtained during the selection campaign undertaken, along with a study of the main sources of noise of the SiPMs including the investigation of a newly observed phenomenon in this field.
Keywords: Cryogenic detectors; Photon detectors for UV, visible and IR photons (solid-state); Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs, CMOS imagers, etc)
|
|
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2024). Improved Measurement of CP Violation Parameters in B0s → J/ψ K+ K- Decays in the Vicinity of the φ(1020) Resonance. Phys. Rev. Lett., 132(5), 051802–12pp.
Abstract: The decay-time-dependent CP asymmetry in B0s -> J=psi(-> mu+mu-)K+K- decays is measured using proton-proton collision data, corresponding to an integrated luminosity of 6 fb-1, collected with the LHCb detector at a center-of-mass energy of 13 TeV. Using a sample of approximately 349 000 B0s signal decays with an invariant K+K- mass in the vicinity of the phi(1020) resonance, the CP-violating phase phi s is measured, along with the difference in decay widths of the light and heavy mass eigenstates of the B0s-B over bar 0s system, Delta Gamma s, and the difference of the average B0s and B0 meson decay widths, Gamma s – Gamma d. The values obtained are phi s = -0.039 +/- 0.022 +/- 0.006 rad, Delta Gamma s = 0.0845 +/- 0.0044 +/- 0.0024 ps-1, and -0.0015 +/- 0.0014 ps-1, where the first uncertainty is statistical and the second systematic. These are the most precise single measurements to date and are consistent with expectations based on the Standard Model and with the previous LHCb analyses of this decay. These results are combined with previous independent LHCb measurements. The phase phi s is also measured independently for each polarization state of the K+K- system and shows no evidence for polarization dependence.
|
|
|
Jungclaus, A., Doornenbal, P., Acosta, J., Vaquero, V., Browne, F., Cortes, M. L., et al. (2024). Position of the single-particle 3/2- state in 135Sn and the N = 90 subshell closure. Phys. Lett. B, 851, 138561–5pp.
Abstract: The decay of excited states of the nucleus Sn-135, with three neutrons outside the doubly-magic Sn-132 core, was studied in an experiment performed at the Radioactive Isotope Beam Factory at RIKEN. Several gamma rays emitted from excited Sn-135 ions were observed following one-neutron and one-neutron-one-proton removal from Sn-136 and Sb-137 beams, respectively, on a beryllium target at relativistic energies. Based on the analogy to 133Sn populated via one-neutron removal from Sn-134, an excitation energy of 695(15) keV is assigned to the 3/2(-) state with strongest single-particle character in 135Sn. This result provides the first direct information about the evolution of the neutron shell structure beyond N = 82 and thus allows for a crucial test of shellmodel calculations in this region. The experimental findings are in full agreement with calculations performed employing microscopic effective two-body interactions derived from CD-Bonn and N3LO nucleon-nucleon potentials, which do not predict a pronounced subshell gap at neutron number N=90. The occurrence of such a gap in Sn-140, i.e., when the 1f(7/2) orbital is completely filled, had been proposed in the past, in analogy to the magicity of Ca-48, featuring a completely filled 0f(7/2) orbital one harmonic oscillator shell below.
|
|