|   | 
Details
   web
Records
Author n_TOF Collaboration (Amaducci, S. et al); Babiano-Suarez, V.; Caballero-Ontanaya, L.; Domingo-Pardo, C.; Ladarescu, I.; Tain, J.L.; Tarifeño-Saldivia, A.
Title Measurement of the 140Ceðn;γþ Cross Section at n_TOF and Its Astrophysical Implications for the Chemical Evolution of the Universe Type Journal Article
Year 2024 Publication Physical Review Letters Abbreviated Journal Phys. Rev. Lett.
Volume 132 Issue 12 Pages 122701 - 8pp
Keywords
Abstract (up) 140Ce(n, gamma) is a key reaction for slow neutron -capture (s -process) nucleosynthesis due to being a bottleneck in the reaction flow. For this reason, it was measured with high accuracy (uncertainty approximate to 5%) at the n_TOF facility, with an unprecedented combination of a high purity sample and low neutron -sensitivity detectors. The measured Maxwellian averaged cross section is up to 40% higher than previously accepted values. Stellar model calculations indicate a reduction around 20% of the s -process contribution to the Galactic cerium abundance and smaller sizeable differences for most of the heavier elements. No variations are found in the nucleosynthesis from massive stars.
Address [Amaducci, S.; Cosentino, L.; Finocchiaro, P.; Brown, A.] INFN, Lab Nazl Sud, Catania, Italy
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0031-9007 ISBN Medium
Area Expedition Conference
Notes WOS:001202102900011 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 6074
Permanent link to this record
 

 
Author n_TOF Collaboration (Amaducci, S. et al); Babiano-Suarez, V.; Caballero-Ontanaya, L.; Domingo-Pardo, C.; Ladarescu, I.; Tain, J.L.
Title First Results of the Ce-140(n,gamma)Ce-141 Cross-Section Measurement at n_TOF Type Journal Article
Year 2021 Publication Universe Abbreviated Journal Universe
Volume 7 Issue 6 Pages 200 - 11pp
Keywords
Abstract (up) An accurate measurement of the Ce-140(n,gamma) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the Ce-140 capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in Ce-140 to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the Ce-140 Maxwellian-averaged cross-section.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes WOS:000665969800001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 4877
Permanent link to this record
 

 
Author n_TOF Collaboration (Torres-Sanchez, P. et al); Babiano-Suarez, V.; Caballero, L.; Domingo-Pardo, C.; Ladarescu, I.; Tain, J.L.
Title Measurement of the 14N(n, p) 14C cross section at the CERN n_TOF facility from subthermal energy to 800 keV Type Journal Article
Year 2023 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 107 Issue 6 Pages 064617 - 15pp
Keywords
Abstract (up) Background: The 14N(n, p) 14C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region, and resonance region. Purpose: We aim to measure the 14N(n, p) 14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and provide calculations of Maxwellian averaged cross sections (MACS). Method: We apply the time-of-flight technique at Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. 10B(n, & alpha;) 7Li and 235U(n, f ) reactions are used as references. Two detection systems are run simultaneously, one on beam and another off beam. Resonances are described with the R-matrix code SAMMY. Results: The cross section was measured from subthermal energy to 800 keV, resolving the first two resonances (at 492.7 and 644 keV). A thermal cross section was obtained (1.809 & PLUSMN; 0.045 b) that is lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations. A 1/v energy dependence of the cross section was confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed determination of the 14N(n, p) cross section over a wide energy range for the first time. We have obtained cross sections with high accuracy (2.5%) from subthermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV.
Address [Torres-Sanchez, Pablo; Praena, Javier; Porras, Ignacio; Ogallar, Francisco] Univ Granada, Granada, Spain, Email: pablotorres@ugr.es
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2469-9985 ISBN Medium
Area Expedition Conference
Notes WOS:001063209900001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5701
Permanent link to this record
 

 
Author n_TOF Collaboration (Moreno-Soto, J. et al); Babiano-Suarez, V.; Caballero-Ontanaya, L.; Domingo-Pardo, C.; Ladarescu, I.; Tain, J.L.
Title Constraints on the dipole photon strength for the odd uranium isotopes Type Journal Article
Year 2022 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 105 Issue 2 Pages 024618 - 14pp
Keywords
Abstract (up) Background: The photon strength functions (PSFs) and nuclear level density (NLD) are key ingredients for calculation of the photon interaction with nuclei, in particular the reaction cross sections. These cross sections are important especially in nuclear astrophysics and in the development of advanced nuclear technologies. Purpose: The role of the scissors mode in the M1 PSF of (well-deformed) actinides was investigated by several experimental techniques. The analyses of different experiments result in significant differences, especially on the strength of the mode. The shape of the low-energy tail of the giant electric dipole resonance is uncertain as well. In particular, some works proposed a presence of the E1 pygmy resonance just above 7 MeV. Because of these inconsistencies additional information on PSFs in this region is of great interest. Methods: The gamma-ray spectra from neutron-capture reactions on the U-234, U-236, and U-238 nuclei have been measured with the total absorption calorimeter of the n_TOF facility at CERN. The background-corrected sum-energy and multi-step-cascade spectra were extracted for several isolated s-wave resonances up to about 140 eV. Results: The experimental spectra were compared to statistical model predictions coming from a large selection of models of photon strength functions and nuclear level density. No combination of PSF and NLD models from literature is able to globally describe our spectra. After extensive search we were able to find model combinations with modified generalized Lorentzian (MGLO) E1 PSF, which match the experimental spectra as well as the total radiative widths. Conclusions: The constant temperature energy dependence is favored for a NLD. The tail of giant electric dipole resonance is well described by the MGLO model of the E1 PSF with no hint of pygmy resonance. The M1 PSF must contain a very strong, relatively wide, and likely double-resonance scissors mode. The mode is responsible for about a half of the total radiative width of neutron resonances and significantly affects the radiative cross section.
Address [Moreno-Soto, J.; Berthoumieux, E.; Dupont, E.; Gunsing, F.; Bacak, M.] Univ Paris Saclay, CEA Irfu, F-91191 Gif Sur Yvette, France, Email: jmoreno53@us.es;
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2469-9985 ISBN Medium
Area Expedition Conference
Notes WOS:000810791100001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5278
Permanent link to this record
 

 
Author Lerendegui-Marco, J.; Balibrea-Correa, J.; Babiano-Suarez, V.; Ladarescu, I.; Domingo-Pardo, C.
Title Towards machine learning aided real-time range imaging in proton therapy Type Journal Article
Year 2022 Publication Scientific Reports Abbreviated Journal Sci Rep
Volume 12 Issue 1 Pages 2735 - 17pp
Keywords
Abstract (up) Compton imaging represents a promising technique for range verification in proton therapy treatments. In this work, we report on the advantageous aspects of the i-TED detector for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been specifically designed for neutron-capture nuclear physics experiments, which are characterized by gamma-ray energies spanning up to 5-6 MeV, rather low gamma-ray emission yields and very intense neutron induced gamma-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high gamma-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl3 crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr3. Its high time-resolution (CRT similar to 500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED Compton module features two detection planes of very large LaCl3 monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1 MeV gamma-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10(8) protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy gamma-rays is compensated by means of machine-learning based algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.
Address [Lerendegui-Marco, Jorge; Balibrea-Correa, Javier; Babiano-Suarez, Victor; Ladarescu, Ion; Domingo-Pardo, Cesar] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain, Email: jorge.lerendegui@ific.uv.es
Corporate Author Thesis
Publisher Nature Portfolio Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2045-2322 ISBN Medium
Area Expedition Conference
Notes WOS:000757537100018 Approved no
Is ISI yes International Collaboration no
Call Number IFIC @ pastor @ Serial 5136
Permanent link to this record
 

 
Author n_TOF Collaboration (Patronis, N. et al); Babiano-Suarez, V.; Balibrea Correa, J.; Domingo-Pardo, C.; Ladarescu, I.; Lerendegui-Marco, J.
Title Status report of the n_TOF facility after the 2nd CERN long shutdown period Type Journal Article
Year 2023 Publication EPJ Techniques and Instrumentation Abbreviated Journal EPJ Tech. Instrum.
Volume 10 Issue 1 Pages 13 - 10pp
Keywords Neutron time of flight; Spallation target; Nuclear astrophysics; Neutron physics; Neutron induced fission; Neutron reactions
Abstract (up) During the second long shutdown period of the CERN accelerator complex (LS2, 2019-2021), several upgrade activities took place at the nTOF facility. The most important have been the replacement of the spallation target with a next generation nitrogen-cooled lead target. Additionally, a new experimental area, at a very short distance from the target assembly (the NEAR Station) was established. In this paper, the core commissioning actions of the new installations are described. The improvement in the nTOF infrastructure was accompanied by several detector development projects. All these upgrade actions are discussed, focusing mostly on the future perspectives of the n_TOF facility. Furthermore, some indicative current and future measurements are briefly reported.
Address [Patronis, N.; Goula, S.; Eleme, Z.; Stamati, M. E.; Vagena, E.] Univ Ioannina, Ioannina, Greece, Email: nikolaos.patronis@cern.ch
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2195-7045 ISBN Medium
Area Expedition Conference
Notes WOS:001008786600001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5591
Permanent link to this record
 

 
Author Babiano, V.; Balibrea, J.; Caballero, L.; Calvo, D.; Ladarescu, I.; Mira Prats, S.; Domingo-Pardo, C.
Title First i-TED demonstrator: A Compton imager with Dynamic Electronic Collimation Type Journal Article
Year 2020 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A
Volume 953 Issue Pages 163228 - 9pp
Keywords Compton imaging; Position-sensitive detectors; Monolithic crystals; Silicon photomultiplier
Abstract (up) i-TED consists of both a total energy detector and a Compton camera primarily intended for the measurement of neutron capture cross sections by means of the simultaneous combination of neutron time-of-flight (TOF) and gamma-ray imaging techniques. TOF allows one to obtain a neutron-energy differential capture yield, whereas the imaging capability is intended for the discrimination of radiative background sources, that have a spatial origin different from that of the capture sample under investigation. A distinctive feature of i-TED is the embedded Dynamic Electronic Collimation (DEC) concept, which allows for a trade-off between efficiency and image resolution. Here we report on some general design considerations and first performance characterization measurements made with an i-TED demonstrator in order to explore its gamma-ray detection and imaging capabilities.
Address [Babiano, V; Balibrea, J.; Caballero, L.; Calvo, D.; Ladarescu, I; Mira Prats, S.; Domingo-Pardo, C.] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain, Email: domingo@ific.uv.es
Corporate Author Thesis
Publisher Elsevier Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0168-9002 ISBN Medium
Area Expedition Conference
Notes WOS:000506419900045 Approved no
Is ISI yes International Collaboration no
Call Number IFIC @ pastor @ Serial 4250
Permanent link to this record
 

 
Author Babiano-Suarez, V. et al; Lerendegui-Marco, J.; Balibrea-Correa, J.; Caballero, L.; Calvo, D.; Ladarescu, I.; Real, D.; Domingo-Pardo, C.
Title Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques Type Journal Article
Year 2021 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A
Volume 57 Issue 6 Pages 197 - 17pp
Keywords
Abstract (up) i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in (n, gamma) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim, the Au-197(n, gamma) and Fe-56(n, gamma) reactions were studied at CERN n_TOF using an i-TED demonstrator based on three position-sensitive detectors. Two C6D6 detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of similar to 3 higher detection sensitivity than state-of-the-art C6D6 detectors in the 10 keV neutron-energy region of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and newanalysis methodologies based on Machine-Learning techniques.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6001 ISBN Medium
Area Expedition Conference
Notes WOS:000662881100001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 4875
Permanent link to this record
 

 
Author Balibrea-Correa, J.; Lerendegui-Marco, J.; Calvo, D.; Caballero, L.; Babiano, V.; Ladarescu, I.; Redondo, M.L.; Tain, J.L.; Tolosa, A.; Domingo-Pardo, C.; Calvino, F.; Casanovas, A.; Tarifeño-Saldivia, A.; Alcayne, V.; Cano-Ott, D.; Martinez, T.; Guerrero, C.; Barbagallo, M.; Macina, D.; Bacak, M.
Title A first prototype of C6D6 total-energy detector with SiPM readout for neutron capture time-of-flight experiments Type Journal Article
Year 2021 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A
Volume 985 Issue Pages 164709 - 8pp
Keywords Silicon photomultiplier; Radiation detectors; Time-of-flight; Radiative capture; Total energy detector; Pulse-height weighting technique
Abstract (up) Low efficiency total-energy detectors (TEDs) are one of the main tools for neutron capture cross section measurements utilizing the time-of-flight (TOF) technique. State-of-the-art TEDs are based on a C6D6 liquid-scintillation cell optically coupled to a fast photomultiplier tube. The large photomultiplier tube represents yet a significant contribution to the so-called neutron sensitivity background, which is one of the most conspicuous sources of uncertainty in this type of experiments. Here we report on the development of a first prototype of a TED based on a silicon-photomultiplier (SiPM) readout, thus resulting in a lightweight and much more compact detector. Apart from the envisaged improvement in neutron sensitivity, the new system uses low voltage (+28 V) and low current supply (-50 mA), which is more practical than the-kV supply required by conventional photomultipliers. One important difficulty hindering the earlier implementation of SiPM readout for this type of detector was the large capacitance for the output signal when all pixels of a SiPM array are summed together. The latter leads to long pulse rise and decay times, which are not suitable for time-of-flight experiments. In this work we demonstrate the feasibility of a Schottky-diode multiplexing readout approach, that allows one to preserve the excellent timing properties of SiPMs, hereby paving the way for their implementation in future neutron TOF experiments.
Address [Balibrea-Correa, J.; Lerendegui-Marco, J.; Calvo, D.; Caballero, L.; Babiano, V; Ladarescu, I; Redondo, M. Lopez; Tain, J. L.; Tolosa, A.; Domingo-Pardo, C.] Univ Valencia, Inst Fis Corpuscular, CSIC, Valencia, Spain, Email: dacaldia@ific.uv.es;
Corporate Author Thesis
Publisher Elsevier Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0168-9002 ISBN Medium
Area Expedition Conference
Notes WOS:000592358200019 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 4638
Permanent link to this record
 

 
Author n_TOF Collaboration (Sosnin, N.V. et al.); Babiano-Suarez, V.; Caballero, L.; Domingo-Pardo, C.; Ladarescu, I.; Tain, J.L.
Title Measurement of the 77Se(n,gamma) cross section up to 200 keV at the n_TOF facility at CERN Type Journal Article
Year 2023 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 107 Issue 6 Pages 065805 - 9pp
Keywords
Abstract (up) The 77Se(n,gamma) reaction is of importance for 77Se abundance during the slow neutron capture process in massive stars. We have performed a new measurement of the 77Se radiative neutron capture cross section at the Neutron Time-of-Flight facility at CERN. Resonance capture kernels were derived up to 51 keV and cross sections up to 200 keV. Maxwellian-averaged cross sections were calculated for stellar temperatures between kT = 5 keV and kT = 100 keV, with uncertainties between 4.2% and 5.7%. Our results lead to substantial decreases of 14% and 19% in 77Se abundances produced through the slow neutron capture process in selected stellar models of 15M0 and 2M0, respectively, compared to using previous recommendation of the cross section.
Address [V. Sosnin, N.; Lederer-Woods, C.; Garg, R.; Dietz, M.; Murphy, A. St. J.; Lonsdale, S.; Woods, P. J.] Univ Edinburgh, Sch Phys & Astron, Edinburgh, Scotland, Email: nsosnin@ed.ac.uk
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2469-9985 ISBN Medium
Area Expedition Conference
Notes WOS:001023903800002 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5599
Permanent link to this record