Roser, J., Barrientos, L., Bernabeu, J., Borja-Lloret, M., Muñoz, E., Ros, A., et al. (2022). Joint image reconstruction algorithm in Compton cameras. Phys. Med. Biol., 67(15), 155009–15pp.
Abstract: Objective. To demonstrate the benefits of using an joint image reconstruction algorithm based on the List Mode Maximum Likelihood Expectation Maximization that combines events measured in different channels of information of a Compton camera. Approach. Both simulations and experimental data are employed to show the algorithm performance. Main results. The obtained joint images present improved image quality and yield better estimates of displacements of high-energy gamma-ray emitting sources. The algorithm also provides images that are more stable than any individual channel against the noisy convergence that characterizes Maximum Likelihood based algorithms. Significance. The joint reconstruction algorithm can improve the quality and robustness of Compton camera images. It also has high versatility, as it can be easily adapted to any Compton camera geometry. It is thus expected to represent an important step in the optimization of Compton camera imaging.
|
Borja-Lloret, M., Barrientos, L., Bernabeu, J., Lacasta, C., Muñoz, E., Ros, A., et al. (2023). Influence of the background in Compton camera images for proton therapy treatment monitoring. Phys. Med. Biol., 68(14), 144001–16pp.
Abstract: Objective. Background events are one of the most relevant contributions to image degradation in Compton camera imaging for hadron therapy treatment monitoring. A study of the background and its contribution to image degradation is important to define future strategies to reduce the background in the system. Approach. In this simulation study, the percentage of different kinds of events and their contribution to the reconstructed image in a two-layer Compton camera have been evaluated. To this end, GATE v8.2 simulations of a proton beam impinging on a PMMA phantom have been carried out, for different proton beam energies and at different beam intensities. Main results. For a simulated Compton camera made of Lanthanum (III) Bromide monolithic crystals, coincidences caused by neutrons arriving from the phantom are the most common type of background produced by secondary radiations in the Compton camera, causing between 13% and 33% of the detected coincidences, depending on the beam energy. Results also show that random coincidences are a significant cause of image degradation at high beam intensities, and their influence in the reconstructed images is studied for values of the time coincidence windows from 500 ps to 100 ns. Significance. Results indicate the timing capabilities required to retrieve the fall-off position with good precision. Still, the noise observed in the image when no randoms are considered make us consider further background rejection methods.
|
Hueso-Gonzalez, F., Berthold, J., Wohlfahrt, P., Bortfeld, T., Khamfongkhruea, C., Tattenberg, S., et al. (2024). Inter-center comparison of proton range verification prototypes with an anthropomorphic head phantom. Phys. Med. Biol., 69(22), 225010–14pp.
Abstract: Objective. To compare in reproducible and equalized conditions the performance of two independent proton range verification systems based on prompt gamma-ray detectors from two different proton therapy centers. Approach. An anthropomorphic head phantom with calibrated stopping power, serving as ground truth, was irradiated with comparable treatment plans, spot positions and energies in both facilities. Clinical beam current, tumor contour and dose were used. The absolute range measurement was compared to the expected value according to the ground truth. The statistical precision was assessed by repeating each measurement ten times. Sensitivity to relative range shifts was evaluated by introducing 2 mm and 5 mm plastic slabs on half of the field. Main results. The resulting absolute range accuracy was within 2.4 mm in all cases. Relative range shifts were detected with deviations lower than 14%. Significance. The performance of both systems was deemed worthy of clinical application for the detection of range deviations. This study represents the first comparison of independent prompt gamma-ray-based proton range verification systems under equalized conditions with realistic treatment fields and beam currents.
|
Kasprzak, J., Roser, J., Werner, J., Kohlhase, N., Bolke, A., Kaufmann, L. M., et al. (2025). Regularized origin ensemble with a beam prior for range verification in particle therapy with Compton-camera data. Phys. Med. Biol., 70(7), 075009–24pp.
Abstract: Objective. In particle therapy (PT), several methods are being investigated to help reduce range margins and identify deviations from the original treatment plan, such as prompt-gamma imaging with Compton cameras (CC). To reconstruct the images, the Origin Ensemble (OE) algorithm is commonly used. In the context of PT, artifacts and strong noise often affect CC images. To improve the ability of OE to identify range shifts, and also to enhance image quality, we propose to regularize OE using beam a-priori knowledge (beam prior). Approach. We implemented the beam prior to OE using the class of Gibbs' distribution functions. For evaluation, Monte-Carlo simulations of centered and off-center beams with therapeutic energies impinging on a PMMA target were conducted in GATE. To introduce range shifts, air layers were introduced into the target. In addition, the effect of a bone layer, closer to a realistic scenario, was investigated. OE with the beam prior (BP-OE) and conventional OE (reference) were compared using the spill-over-ratio (SOR) as well as shifts in the distal falloff in projections using cubic splines with Chebyshev nodes. Main results. BP-OE improved the shift estimates by up to 11% compared to conventional OE for centered and up to 250% with off-centered beams. BP-OE decreased the image noise level, improving the SOR significantly by up to 96%. Significance. BP-OE applied to CC data can improve shift estimations compared to conventional OE. The developed Gibbs-based regularization framework also allows further prior functions to be included into OE, for instance, smoothing or edge-preserving priors. BP-OE could be extended to PET-based range verification or multiple-beam scenarios.
|
Montanari, D. et al, & Gadea, A. (2011). Probing the nature of particle-core couplings in Ca-49 with gamma spectroscopy and heavy-ion transfer reactions. Phys. Lett. B, 697(4), 288–293.
Abstract: Neutron rich nuclei around Ca-48 have been measured with the CLARA-PRISMA setup, making use of Ca-48 on Ni-64 binary reactions, at 5.9 MeV/A. Angular distributions of gamma rays give evidence, in several transfer channels, for a large spin alignment (approximate to 70%) perpendicular to the reaction plane, making it possible to firmly establish spin and parities of the excited states. In the case of Ca-49, states arising from different types of particle-core couplings are, for the first time, unambiguously identified on basis of angular distribution, polarization and lifetime measurements. Shell model and particle-vibration coupling calculations are used to pin down the nature of the states. Evidence is found for the presence, in the same excitation energy region, of two types of coupled states, i.e. single particle coupled to either Ca-48 or Ca-50 simple configurations, and particle-vibration coupled states based on the 3- phonon of Ca-48.
|