Heidari, N., Hassanabadi, H., Araujo, A. A., & Kriz, J. (2024). Exploring non-commutativity as a perturbation in the Schwarzschild black hole: quasinormal modes, scattering, and shadows. Eur. Phys. J. C, 84(6), 566–11pp.
Abstract: In this work, by a novel approach to studying the scattering of a Schwarzschild black hole, the non-commutativity is introduced as perturbation. We begin by reformulating the Klein-Gordon equation for the scalar field in a new form that takes into account the deformed non-commutative spacetime. Using this formulation, an effective potential for the scattering process is derived. To calculate the quasinormal modes, we employ the WKB method and also utilize fitting techniques to investigate the impact of non-commutativity on the scalar quasinormal modes. We thoroughly analyze the results obtained from these different methods. Moreover, the greybody factor and absorption cross section are investigated. Additionally, we explore the behavior of null geodesics in the presence of non-commutativity. Specifically, we examine the photonic, and shadow radius as well as the light trajectories for different non-commutative parameters. Therefore, by addressing these various aspects, we aim to provide a comprehensive understanding of the influence of non-commutativity on the scattering of a Schwarzschild-like black hole and its implications for the behavior of scalar fields and light trajectories.
|
Aguilar, A. C., Ferreira, M. N., Papavassiliou, J., & Santos, L. R. (2024). Four-gluon vertex in collinear kinematics. Eur. Phys. J. C, 84(7), 676–27pp.
Abstract: To date, the four-gluon vertex is the least explored component of the QCD Lagrangian, mainly due to the vast proliferation of Lorentz and color structures required for its description. In this work we present a nonperturbative study of this vertex, based on the one-loop dressed Schwinger-Dyson equation obtained from the 4PI effective action. A vast simplification is brought about by resorting to “collinear” kinematics, where all momenta are parallel to each other, and by appealing to the charge conjugation symmetry in order to eliminate certain color structures. Out of the fifteen form factors that comprise the transversely-projected version of this vertex, two are singled out and studied in detail; the one associated with the classical tensorial structure is moderately suppressed in the infrared regime, while the other diverges logarithmically at the origin. Quite interestingly, both form factors display the property known as “planar degeneracy” at a rather high level of accuracy. With these results we construct an effective charge that quantifies the strength of the four-gluon interaction, and compare it with other vertex-derived charges from the gauge sector of QCD.
|
Pich, A. (2021). Challenges for tau physics at the TeraZ. Eur. Phys. J. Plus, 136(11), 1117–8pp.
Abstract: The very high statistics, low backgrounds and clean back-to-back kinematics of a TeraZ facility would provide an optimal laboratory for precision measurements of the tau properties. A few important topics in tau physics where very relevant contributions could be made are highlighted.
|
Fuster-Martinez, N., Assmann, R. W., Bruce, R., Giovannozzi, M., Hermes, P., Mereghetti, A., et al. (2022). Beam-based aperture measurements with movable collimator jaws as performance booster of the CERN Large Hadron Collider. Eur. Phys. J. Plus, 137(3), 305–20pp.
Abstract: The beam aperture of a particle accelerator defines the clearance available for the circulating beams and is a parameter of paramount importance for the accelerator performance. At the CERN Large Hadron Collider (LHC), the knowledge and control of the available aperture is crucial because the nominal proton beams carry an energy of 362 MJ stored in a superconducting environment. Even a tiny fraction of beam losses could quench the superconducting magnets or cause severe material damage. Furthermore, in a circular collider, the performance in terms of peak luminosity depends to a large extent on the aperture of the inner triplet quadrupoles, which are used to focus the beams at the interaction points. In the LHC, this aperture represents the smallest aperture at top-energy with squeezed beams and determines the maximum potential reach of the peak luminosity. Beam-based aperture measurements in these conditions are difficult and challenging. In this paper, we present different methods that have been developed over the years for precise beam-based aperture measurements in the LHC, highlighting applications and results that contributed to boost the operational LHC performance in Run 1 (2010-2013) and Run 2 (2015-2018)
|
Balibrea-Correa, J., Lerendegui-Marco, J., Ladarescu, I., Guerrero, C., Rodriguez-Gonzalez, T., Jimenez-Ramos, M. C., et al. (2022). Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification. Eur. Phys. J. Plus, 137(11), 1258–18pp.
Abstract: We report on a hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA cyclotron facility using a set of two synchronous Compton imagers and different target materials. The time structure of the 18 MeV proton beam was shaped with a series of beam-on and beam-off intervals, thereby mimicking a pulsed proton beam on a long time scale. During beam-on intervals, Compton imagingwas performed utilizing the high energy. -rays promptly emitted from the nuclear reactions occurring in the targets. In the course of the beam-off intervals in situ positron-emission tomography was accomplished with the same imagers using the beta+ decay of activated nuclei. The targets used were stacks of different materials covering also various proton ranges and energies. A systematic study on the performance of these two complementary imaging techniques is reported and the experimental results interpreted on the basis ofMonte Carlo calculations. The results demonstrate the possibility to combine both imaging techniques in a concomitant way, where high-efficiency prompt-gamma imaging is complemented with the high spatial accuracy of PET. Empowered by these results we suggest that a pulsed beam with a suitable duty cycle, in conjunction with in situ Compton- and PET-imaging may help to attain complementary information and quasi real-time range monitoring with high accuracy.
|
Fanchiotti, H., Garcia Canal, C. A., Traini, M., & Vento, V. (2022). Signatures of excited monopolium. Eur. Phys. J. Plus, 137(12), 1316–19pp.
Abstract: We study electromagnetic properties of particles with magnetic moment and no charge using their behavior when traversing coils and solenoids. These particles via the Faraday-Lenz law create a current whose energy we calculate. We analyze both the case of very long lived, almost stable, particles and those with a finite lifetime. We use this development to study the behavior of monopolium a monopole-antimonopole bound state in its excited states.
|
Llosa, G., & Rafecas, M. (2023). Hybrid PET/Compton-camera imaging: an imager for the next generation. Eur. Phys. J. Plus, 138(3), 214–19pp.
Abstract: Compton cameras can offer advantages over gamma cameras for some applications, since they are well suited for multitracer imaging and for imaging high-energy radiotracers, such as those employed in radionuclide therapy. While in conventional clinical settings state-of-the-art Compton cameras cannot compete with well-established methods such as PET and SPECT, there are specific scenarios in which they can constitute an advantageous alternative. The combination of PET and Compton imaging can benefit from the improved resolution and sensitivity of current PET technology and, at the same time, overcome PET limitations in the use of multiple radiotracers. Such a system can provide simultaneous assessment of different radiotracers under identical conditions and reduce errors associated with physical factors that can change between acquisitions. Advances are being made both in instrumentation developments combining PET and Compton cameras for multimodal or three-gamma imaging systems, and in image reconstruction, addressing the challenges imposed by the combination of the two modalities or the new techniques. This review article summarizes the advances made in Compton cameras for medical imaging and their combination with PET.
|
Moreira, A. R. P., Belchior, F. M., Maluf, R. V., & Almeida, C. A. S. (2023). Bulk fields localization on thick string-like brane in f(T) gravity. Eur. Phys. J. Plus, 138(8), 730–15pp.
Abstract: This paper aims to investigate the influence of torsion on bulk fields in the codimension two thick brane in f(T) modified teleparallel gravity. It is shown that the brane supports the localization of gauge field zero mode without an extra coupling. However, Kalb-Ramond and fermionic fields require a suitable coupling. Then, it is proposed a geometrical coupling based on results in 5D thick brane in modified teleparallel gravities. The Kalb-Ramond field is coupled to torsion scalar T through a gauge-invariant interaction. For the case of fermionic fields, we study the Dirac fermions and gravitino with a derivative geometrical coupling. For all of the fields, it obtained massive and resonant modes by employing the Schodinger-like approach.
|
Araújo, M. C., Furtado, J., & Maluf, R. V. (2024). Casimir effect in a Lorentz-violating tensor extension of a scalar field theory. Eur. Phys. J. Plus, 139(2), 165–12pp.
Abstract: This paper investigates the Casimir energy modifications due to the Lorentz-violating CPT-even contribution in an extension of the scalar QED. We have considered the complex scalar field satisfying Dirichlet boundary conditions between two parallel plates separated by a small distance. An appropriate tensor parametrization allowed us to study the Casimir effect in three different configurations: isotropic, anisotropic parity-odd, and anisotropic parity-even. We have shown that the Lorentz-violating contributions can promote either an increase or a decrease in the Casimir energy evaluated in the isotropic configuration, depending on whether the violation parameters are taking as positive or negative values. On the other hand, for the anisotropic parity-even case the Casimir energy only decreases, while for the anisotropic parity-odd cases it only increases. Therefore, from these last two results it seems that the Casimir energy is sensitive to the parity of Lorentz-violating coefficients.
|
Fanchiotti, H., Garcia Canal, C. A., & Vento, V. (2023). Energy loss of monopolium in a medium. Eur. Phys. J. Plus, 138(9), 850–11pp.
Abstract: We study the energy loss of excited monopolium in an atomic medium. We perform a classical calculation in line with a similar calculation performed for charged particles which leads in the non-relativistic limit to the Bethe-Bloch formula except for the density dependence of the medium, which we do not consider in this paper. Our result shows that for maximally deformed Rydberg states, the ionization of monopolium in a light atomic medium is similar to that of light ions.
|