toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Kim, Y.H. et al; Perez-Vidal, R.M. doi  openurl
  Title Prompt-delayed gamma-ray spectroscopy with AGATA, EXOGAM and VAMOS plus Type Journal Article
  Year 2017 Publication European Physical Journal A Abbreviated Journal (up) Eur. Phys. J. A  
  Volume 53 Issue 8 Pages 162 - 8pp  
  Keywords  
  Abstract A new experimental setup to measure prompt-delayed gamma-ray coincidences from isotopically identified fission fragments, over a wide time range of 100 ns-200 μs, is presented. The fission fragments were isotopically identified, on an event-by-event basis, using the VAMOS++ large acceptance spectrometer. The prompt gamma rays emitted at the target position and corresponding delayed gamma rays emitted at the focal plane of the spectrometer were detected using, respectively, thirty two crystals of the AGATA gamma-ray tracking array and seven EXOGAM HPGe Clover detectors. Fission fragments produced in fusion and transfer-induced fission reactions, using a U-238 beam at an energy of 6.2MeV/u impinging on a Be-9 target, were used to characterize and qualify the performance of the detection system.  
  Address [Kim, Y. H.; Lemasson, A.; Rejmund, M.; Navin, A.; Michelagnoli, C.; Clement, E.; De France, G.; Goupil, J.; Jacquot, B.; Li, H. J.; Menager, L.; Morel, V.; Ropert, J.; Schmitt, C.] CEA DRF CNRS IN2P3, GANIL, Bd Henri Becquerel,BP 55027, F-14076 Caen 5, France, Email: yunghee.kim@ganil.fr;  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000408087100003 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3257  
Permanent link to this record
 

 
Author Lewandowski, L.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Clemente, E.; Eberth, J.; Hess, H.; Michelagnoli, C.; Li, H.; Perez-Vidal, R.M.; Zielinska, M. doi  openurl
  Title Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors Type Journal Article
  Year 2019 Publication European Physical Journal A Abbreviated Journal (up) Eur. Phys. J. A  
  Volume 55 Issue 5 Pages 81 - 13pp  
  Keywords  
  Abstract The performance of the Pulse-Shape Analysis (PSA) in AGATA HPGe detectors was investigated and improved employing a -ray source measurement based on e+e- annihilation radiation after decays of Na-22 by + decay. The first interaction positions of the two 511keV rays were determined and the connecting line of these two positions was compared to the known source position as a measure for the PSA performance. The position resolution and its dependence on the PSA parameters were investigated by varying most relevant input quantities: the charge carrier mobility of the holes, the response of the employed measuring electronics especially the preamplifier rise time. The relative statistical weight of charge signals and transient signals was scrutinized. The optimal distance metric of the grid-search algorithm and its impact on the position resolution were determined.  
  Address [Lewandowski, L.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Eberth, J.; Hess, H.] Univ Cologne, Inst Kernphys, Zulpicher Str 77, D-50937 Cologne, Germany, Email: preiter@ikp.uni-koeln.de  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000468893200002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4023  
Permanent link to this record
 

 
Author Perez-Vidal, R.M.; Galtarossa, F.; Mijatovic, T.; Szilner, S.; Zanon, I.; Brugnara, D.; Pellumaj, J.; Ciemala, M.; Valiente-Dobon, J.J.; Corradi, L.; Clement, E.; Leoni, S.; Fornal, B.; Siciliano, M.; Gadea, A. doi  openurl
  Title Nuclear structure advancements with multi-nucleon transfer reactions Type Journal Article
  Year 2023 Publication European Physical Journal A Abbreviated Journal (up) Eur. Phys. J. A  
  Volume 59 Issue 5 Pages 114 - 15pp  
  Keywords  
  Abstract Multi-Nucleon Transfer (MNT) reactions have been used for decades as a reaction mechanism, in order to populate excited states in nuclei far from stability and to perform nuclear structure studies. Nevertheless, the development of set-ups involving high acceptance tracking magnetic spectrometers (mainly existing in Europe), coupled with the Advanced GAmma Tracking Array (AGATA) opens new possibilities, especially if they are used in conjunction with high-intensity stable beams or ISOL RIBs. In this article, we will discuss the capabilities of such set-ups aiming at different goals, including complete information in high-resolution spectroscopy as well as lifetime measurements.  
  Address [Perez-Vidal, R. M.; Gadea, A.] Univ Valencia, Inst Fis Corpuscular, CSIC, Valencia 46980, Spain, Email: gadea@ific.uv.es  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000994875500001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5537  
Permanent link to this record
 

 
Author Labiche, M.; Ljungvall, J.; Crespi, F.C.L.; Chen, S.; Bordes, J.; Goasduff, A.; Bottoni, S.; Gamba, E.; Perez-Vidal, R.M.; Bentley, M.A. doi  openurl
  Title Simulation of the AGATA spectrometer and coupling with ancillary detectors Type Journal Article
  Year 2023 Publication European Physical Journal A Abbreviated Journal (up) Eur. Phys. J. A  
  Volume 59 Issue 7 Pages 158 - 12pp  
  Keywords  
  Abstract The design study of the AGATA array began with the development of the AGATA simulation code using GEANT4. The latter played a key part in the final design of the array and provided a cost effective solution for the early development of the tracking algorithm. The code has since been maintained and developed by the collaboration to provide more realistic simulations, with reaction chambers, ancillary detectors and surrounding mechanical structures completing the entire setup.  
  Address [Labiche, M.] Daresbury Lab, Sci & Technol Facil Council STFC, Keckwick Lane, Warrington, England, Email: marc.labiche@stfc.ac.uk  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:001032437400002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5597  
Permanent link to this record
 

 
Author Mengoni, D.; Duenas, J.A.; Assie, M.; Boiano, C.; John, P.R.; Aliaga, R.J.; Beaumel, D.; Capra, S.; Gadea, A.; Gonzales, V.; Gottardo, A.; Grassi, L.; Herrero-Bosch, V.; Houdy, T.; Martel, I.; Parkar, V.V.; Perez-Vidal, R.M.; Pullia, A.; Sanchis, E.; Triossi, A.; Valiente-Dobon, J.J. doi  openurl
  Title Digital pulse-shape analysis with a TRACE early silicon prototype Type Journal Article
  Year 2014 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal (up) Nucl. Instrum. Methods Phys. Res. A  
  Volume 764 Issue Pages 241-246  
  Keywords Silicon detector; Light-charged particles; Digital pulse shape analysis; Particle identification; Gamma-ray spectroscopy  
  Abstract A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination.  
  Address [Mengoni, D.; John, P. R.; Grassi, L.] Univ Padua, Dipartimento Fis & Astron, I-35131 Padua, Italy  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0168-9002 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000341987000030 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 1929  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva