|   | 
Details
   web
Records
Author Studen, A.; Burdette, D.; Chesi, E.; Cindro, V.; Clinthorne, N.H.; Cochran, E.; Grosicar, B.; Kagan, H.; Lacasta, C.; Linhart, V.; Mikuz, M.; Stankova, V.; Weilhammer, P.; Zontar, D.
Title Timing performance of the silicon PET insert probe Type Journal Article
Year 2010 Publication Radiation Protection Dosimetry Abbreviated Journal (down) Radiat. Prot. Dosim.
Volume 139 Issue 1-3 Pages 199-203
Keywords
Abstract Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 256 square pads (1.4 mm side), coupled with two VATAGP7s, application-specific integrated circuits. The detector material and electronics are the same that will be used for the final probe. The model was exposed to 511 keV annihilation photons from an Na-22 source, and a scintillator (LYSO)-PMT assembly was used as a timing reference. Results were compared with the simulation, consisting of four parts: (i) GEANT4 implemented realistic tracking of electrons excited by annihilation photon interactions in silicon, (ii) calculation of propagation of secondary ionisation (electron-hole pairs) in the sensor, (iii) estimation of the shape of the current pulse induced on surface electrodes and (iv) simulation of the first electronics stage. A very good agreement between the simulation and the measurements were found. Both indicate reliable performance of the final probe at timing windows down to 20 ns.
Address [Studen, A.; Cindro, V.; Grosicar, B.; Mikuz, M.; Zontar, D.] Jozef Stefan Inst, SI-1000 Ljubljana, Slovenia, Email: andrej.studen@ijs.si
Corporate Author Thesis
Publisher Oxford Univ Press Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0144-8420 ISBN Medium
Area Expedition Conference
Notes ISI:000277738200035 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ elepoucu @ Serial 449
Permanent link to this record
 

 
Author Hoeschen, C.; Mattsson, S.; Cantone, M.C.; Mikuz, M.; Lacasta, C.; Ebel, G.; Clinthorne, N.; Giussani, A.
Title Minimising activity and dose with enhanced image quality by radiopharmaceutical administrations Type Journal Article
Year 2010 Publication Radiation Protection Dosimetry Abbreviated Journal (down) Radiat. Prot. Dosim.
Volume 139 Issue 1-3 Pages 250-253
Keywords
Abstract Owing to the introduction of new diagnostic procedures, such as computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT), the individual dose caused by medical exposures has grown rapidly in the last years. This is especially a subject to radiation protection for nuclear medical diagnosis, since in this case radiopharmaceuticals are administered to the patient, meaning not only a radiation exposure to the diseased tissue but also to the healthy tissues of large parts of the body. 'Minimizing Activity and Dose with Enhanced Image quality by Radiopharmaceutical Administrations' (MADEIRA) is a project cofunded by the European Commission within the Seventh Euratom Framework Programme that aims to improve three-dimensional (3D) nuclear medical imaging technologies significantly. MADEIRA is aiming to improve the efficacy and safety of 3D PET and SPECT functional imaging by optimising the spatial resolution and the signal-to-noise ratio, improving the knowledge of the temporal variation of the radiopharmaceuticals' uptake in and clearance from tumourous and healthy tissues, and evaluation of the corresponding patient dose. Using an optimised imaging procedure that improves the information gained per unit administered dose, MADEIRA aims especially to reduce the dose to healthy tissues of the patient. In this paper, an overall summary of the current achievements will be presented.
Address [Hoeschen, C.; Giussani, A.] German Res Ctr Environm Hlth, Helmholtz Zentrum Munchen, Inst Radiat Protect, D-85764 Neuherberg, Germany, Email: christoph.hoeschen@helmholtz-muenchen.de
Corporate Author Thesis
Publisher Oxford Univ Press Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0144-8420 ISBN Medium
Area Expedition Conference
Notes ISI:000277738200045 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ elepoucu @ Serial 450
Permanent link to this record
 

 
Author Yamagata-Sekihara, J.; Cabrera, D.; Vicente Vacas, M.J.; Hirenzaki, S.
Title Formation of phi Mesic Nuclei Type Journal Article
Year 2010 Publication Progress of Theoretical Physics Abbreviated Journal (down) Prog. Theor. Phys.
Volume 124 Issue 1 Pages 147-162
Keywords
Abstract We consider the structure and formation of the phi mesic nuclei to investigate the experimental feasibility of the observation of signals of the phi mesic nucleus formation. phi mesic nuclei are considered to be very important objects to study the in-medium modification of the phi-meson spectral function at finite density. We consider ((p) over bar, phi), (gamma, p) and (pi(-), n) reactions to produce a phi-meson inside the nucleus and evaluate the effects of its medium modifications to the reaction cross sections. We also estimate the consequences of the uncertainties of the in-medium (K) over bar self-energy to the phi-nucleus interaction. We find that it may be possible to see peak structures in the reaction spectra for the strong attractive potential cases. On the other hand, for strong absorptive interaction cases with relatively weak attraction, it is very difficult to observe clear peaks and we may need to know the spectrum shape in a wide energy region to deduce the properties of phi.
Address [Yamagata-Sekihara, Junko; Vacas, Manuel J. Vicente] Univ Valencia, CSIC, Dept Fis Teor, E-46071 Valencia, Spain
Corporate Author Thesis
Publisher Progress Theoretical Physics Publication Office Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0033-068x ISBN Medium
Area Expedition Conference
Notes ISI:000280654900007 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ elepoucu @ Serial 396
Permanent link to this record
 

 
Author ATF Collaboration (Bambade, P. e al); Alabau Pons, M.; Faus-Golfe, A.
Title Present status and first results of the final focus beam line at the KEK Accelerator Test Facility Type Journal Article
Year 2010 Publication Physical Review Special Topics-Accelerators and Beams Abbreviated Journal (down) Phys. Rev. Spec. Top.-Accel. Beams
Volume 13 Issue 4 Pages 042801 - 10pp
Keywords
Abstract ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U. S. scientists. The present status and first results are described.
Address [Bambade, P.; Renier, Y.; Rimbault, C.] Univ Paris 11, CNRS, LAL, IN2P3, F-91405 Orsay, France
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1098-4402 ISBN Medium
Area Expedition Conference
Notes ISI:000278150700009 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ elepoucu @ Serial 436
Permanent link to this record
 

 
Author MiniBooNE Collaboration (Aguilar-Arevalo, A.A. et al); Sorel, M.
Title Event Excess in the MiniBooNE Search for (nu)over-bar(mu) -> (nu)over-bar(e) Oscillations Type Journal Article
Year 2010 Publication Physical Review Letters Abbreviated Journal (down) Phys. Rev. Lett.
Volume 105 Issue 18 Pages 181801 - 5pp
Keywords
Abstract The MiniBooNE experiment at Fermilab reports results from a search for (nu) over bar (mu) -> (nu) over bar (e) oscillations, using a data sample corresponding to 5.66 x 10(20) protons on target. An excess of 20.9 +/- 14.0 events is observed in the energy range 475 < E-nu(QE) < 1250 MeV, which, when constrained by the observed <(nu)over bar>(mu) events, has a probability for consistency with the background-only hypothesis of 0.5%. On the other hand, fitting for (nu) over bar (mu) -> (nu) over bar (e) oscillations, the best-fit point has chi(2) probability of 8.7%. The data are consistent with (nu) over bar (mu) -> (nu) over bar (e) oscillations in the 0.1 to 1.0 eV(2) Delta m(2) range and with the evidence for antineutrino oscillations from the Liquid Scintillator Neutrino Detector at Los Alamos National Laboratory.
Address [Dharmapalan, R.; Perevalov, D.; Stancu, I.] Univ Alabama, Tuscaloosa, AL 35487 USA
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0031-9007 ISBN Medium
Area Expedition Conference
Notes ISI:000283492000002 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 263
Permanent link to this record