PT Journal AU Egea Canet, FJea Gadea, A Huyuk, T TI A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors SO IEEE Transactions on Nuclear Science JI IEEE Trans. Nucl. Sci. PY 2015 BP 1056 EP 1062 VL 62 IS 3 DI 10.1109/TNS.2015.2433021 LA English DE Acquisition in HP-Ge detectors; high-speed ADCs; low-noise electronics design AB This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy. ER