%0 Journal Article %T Studies of the muon momentum calibration and performance of the ATLAS detector with pp collisions at √s=13 TeV %A ATLAS Collaboration (Aad, G. et al %A Amos, K. R. %A Aparisi Pozo, J. A. %A Bailey, A. J. %A Bouchhar, N. %A Cabrera Urban, S. %A Cantero, J. %A Cardillo, F. %A Castillo Gimenez, V. %A Chitishvili, M. %A Costa, M. J. %A Didenko %A Escobar, C. %A Fiorini, L. %A Fullana Torregrosa, E. %A Fuster, J. %A Garcia, C. %A Garcia Navarro, J. E. %A Gomez Delegido, A. J. %A Gonzalez de la Hoz, S. %A Gonzalvo Rodriguez, G. R. %A Guerrero Rojas, J. G. R. %A Lacasta, C. %A Marti-Garcia, S. %A Martinez Agullo, P. %A Miralles Lopez, M. %A Mitsou, V. A. %A Monsonis Romero, L. %A Moreno Llacer, M. %A Munoz Perez, D. %A Navarro-Gonzalez, J. %A Poveda, J. %A Prades Ibañez, A. %A Rubio Jimenez, A. %A Ruiz-Martinez, A. %A Sabatini, P. %A Salt, J. %A Sanchez Sebastian, V. %A Sayago Galvan, I. %A Senthilkumar, V. %A Soldevila, U. %A Sanchez, J. %A Torro Pastor, E. %A Valero, A. %A Valiente Moreno, E. %A Valls Ferrer, J. A. %A Varriale, L. %A Villaplana Perez, M. %A Vos, M. %J European Physical Journal C %D 2023 %V 83 %N 8 %I Springer %@ 1434-6044 %G English %F ATLASCollaborationAad_etal2023 %O WOS:001062451200001 %O exported from refbase (https://references.ific.uv.es/refbase/show.php?record=5753), last updated on Sat, 04 Nov 2023 16:23:38 +0000 %X This paper presents the muon momentum calibration and performance studies for the ATLAS detector based on the pp collisions data sample produced at root s = 13 TeV at the LHC during Run 2 and corresponding to an integrated luminosity of 139 fb(-1). An innovative approach is used to correct for potential charge-dependent momentum biases related to the knowledge of the detector geometry, using the Z ->mu(+)mu(-) resonance. The muon momentum scale and resolution are measured using samples of J/psi ->mu(+)mu(-) and Z ->mu(+)mu(-) events. A calibration procedure is defined and applied to simulated data to match the performance measured in real data. The calibration is validated using an independent sample of Upsilon ->mu(+)mu(-) events. At the Z(J/psi) peak, the momentum scale is measured with an uncertainty at the 0.05% (0.1%) level, and the resolution is measured with an uncertainty at the 1.5% (2%) level. The charge-dependent bias is removed with a dedicated in situ correction for momenta up to 450 GeV with a precision better than 0.03 TeV-1. %R 10.1140/epjc/s10052-023-11584-x %U https://arxiv.org/abs/2212.07338 %U https://doi.org/10.1140/epjc/s10052-023-11584-x %P 686 - 37pp