%0 Journal Article %T Online Rn-222 removal by cryogenic distillation in the XENON100 experiment %A XENON Collaboration (Aprile, E. et al %A Orrigo, S. E. A. %J European Physical Journal C %D 2017 %V 77 %N 6 %I Springer %@ 1434-6044 %G English %F XENONCollaborationAprile+Orrigo2017 %O WOS:000402676000001 %O exported from refbase (https://references.ific.uv.es/refbase/show.php?record=3166), last updated on Thu, 22 Jun 2017 18:09:00 +0000 %X We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant Rn-222 background originating from radon emanation. After inserting an auxiliary 222Rn emanation source in the gas loop, we determined a radon reduction factor of R > 27 (95% C.L.) for the distillation column by monitoring the Rn-222 activity concentration inside the XENON100 detector. %R 10.1140/epjc/s10052-017-4902-x %U http://arxiv.org/abs/1702.06942 %U https://doi.org/10.1140/epjc/s10052-017-4902-x %P 358-8pp