@Article{Caballero_etal2018, author="Caballero, L. and Albiol, F. and Corbi Bellot, A. and Domingo-Pardo, C. and Leganes Nieto, J. L. and Agramunt Ros, J. and Contreras, P. and Monserrate, M. and Olleros Rodriguez, P. and Perez Magan, D. L.", title="Gamma-ray imaging system for real-time measurements in nuclear waste characterisation", journal="Journal of Instrumentation", year="2018", publisher="Iop Publishing Ltd", volume="13", pages="P03016 - 23pp", optkeywords="Inspection with gamma rays; Radiation monitoring", abstract="Acompact, portable and large field-of-viewgamma camera that is able to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities that enable its use it in a variety of nuclear waste characterisation scenarios, such as radioactivity monitoring in nuclear power plants and more specifically for the decommissioning of nuclear facilities. The technical development of this apparatus and some examples of its application in field measurements are reported in this article. The performance of the presented gamma-camera is also benchmarked against other conventional techniques.", optnote="WOS:000428146300006", optnote="exported from refbase (https://references.ific.uv.es/refbase/show.php?record=3540), last updated on Mon, 04 Oct 2021 08:40:49 +0000", issn="1748-0221", doi="10.1088/1748-0221/13/03/P03016", opturl="http://arxiv.org/abs/1801.04108", opturl="https://doi.org/10.1088/1748-0221/13/03/P03016", archivePrefix="arXiv", eprint="1801.04108", language="English" }