@Article{Blanco_etal2012, author="Blanco, A. and Belver, D. and Cabanelas, P. and Diaz, J. and Fonte, P. and Garzon, J. A. and Gil, A. and Gonzalez-Diaz, D. and Koenig, W. and Kolb, B. and Lopes, L. and Palka, M. and Pereira, A. and Traxler, M. and Zumbruch, P.", title="RPC HADES-TOF wall cosmic ray test performance", journal="Nuclear Instruments {\&} Methods in Physics Research A", year="2012", publisher="Elsevier Science Bv", volume="661", pages="S114-S117", optkeywords="Gaseous detectors; Timing; TOF; RPC; HADES", abstract="In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m(2). All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1{\%} (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.", optnote="WOS:000311568900029", optnote="exported from refbase (https://references.ific.uv.es/refbase/show.php?record=1285), last updated on Fri, 25 Jan 2013 15:38:47 +0000", issn="0168-9002", doi="10.1016/j.nima.2010.08.068", opturl="https://doi.org/10.1016/j.nima.2010.08.068", language="English" }