Arnault, P., Macquet, A., Angles-Castillo, A., Marquez-Martin, I., Pina-Canelles, V., Perez, A., et al. (2020). Quantum simulation of quantum relativistic diffusion via quantum walks. J. Phys. A, 53(20), 205303–39pp.
Abstract: Two models are first presented, of a one-dimensional discrete-time quantum walk (DTQW) with temporal noise on the internal degree of freedom (i.e., the coin): (i) a model with both a coin-flip and a phase-flip channel, and (ii) a model with random coin unitaries. It is then shown that both these models admit a common limit in the spacetime continuum, namely, a Lindblad equation with Dirac-fermion Hamiltonian part and, as Lindblad jumps, a chirality flip and a chirality-dependent phase flip, which are two of the three standard error channels for a two-level quantum system. This, as one may call it, Dirac Lindblad equation, provides a model of quantum relativistic spatial diffusion, which is evidenced both analytically and numerically. This model of spatial diffusion has the intriguing specificity of making sense only with original unitary models which are relativistic in the sense that they have chirality, on which the noise is introduced: the diffusion arises via the by-construction (quantum) coupling of chirality to the position. For a particle with vanishing mass, the model of quantum relativistic diffusion introduced in the present work, reduces to the well-known telegraph equation, which yields propagation at short times, diffusion at long times, and exhibits no quantumness. Finally, the results are extended to temporal noises which depend smoothly on position.
|
|
|
Gimenez-Alventosa, V., Gimenez, V., Ballester, F., Vijande, J., & Andreo, P. (2020). Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams. Phys. Med. Biol., 65(20), 205005–11pp.
Abstract: The beam quality correction factork(Q)for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of the International Code of Practice for dosimetry based on standards of absorbed dose to water (IAEA TRS 398). The values reported in this work agree with those in the literature within the uncertainty estimates and are to be included in the average values of the data obtained by different working groups for the forthcoming update of TRS 398.
|
|
|
Archidiacono, M., Giusarma, E., Hannestad, S., & Mena, O. (2013). Cosmic Dark Radiation and Neutrinos. Adv. High. Energy Phys., 2013, 191047–14pp.
Abstract: New measurements of the cosmic microwave background (CMB) by the Planck mission have greatly increased our knowledge about the universe. Dark radiation, a weakly interacting component of radiation, is one of the important ingredients in our cosmological model which is testable by Planck and other observational probes. At the moment, the possible existence of dark radiation is an unsolved question. For instance, the discrepancy between the value of the Hubble constant, H-0, inferred from the Planck data and local measurements of H-0 can to some extent be alleviated by enlarging the minimal ACDM model to include additional relativistic degrees of freedom. From a fundamental physics point of view, dark radiation is no less interesting. Indeed, it could well be one of the most accessible windows to physics beyond the standard model, for example, sterile neutrinos. Here, we review the most recent cosmological results including a complete investigation of the dark radiation sector in order to provide an overview of models that are still compatible with new cosmological observations. Furthermore, we update the cosmological constraints on neutrino physics and dark radiation properties focusing on tensions between data sets and degeneracies among parameters that can degrade our information or mimic the existence of extra species.
|
|
|
Leal, A., Mateo, D., Pi, M., Barranco, M., & Navarro, J. (2013). The structure of mixed He-3-He-4 droplets doped with OCS: A density functional approach. J. Chem. Phys., 139(17), 174308–6pp.
Abstract: We have investigated the structure and energetics of mixed He-3-He-4 droplets doped with a carbonyl sulfide molecule within a density functional approach considering a small but finite temperature of 0.1 K. The molecule is treated as an external field to which the helium droplet is attached. The energetics and appearance of these droplets are discussed for selected numbers of helium atoms, identifying the first magic numbers of the fermionic component.
|
|
|
Punzi, G., Baldini, W., Bassi, G., Contu, A., Fantechi, R., He, J. B., et al. (2024). Detector-embedded reconstruction of complex primitives using FPGAs. Nucl. Instrum. Methods Phys. Res. A, 1069, 169782–4pp.
Abstract: The slowdown of Moore's law and the growing requirements of future HEP experiments with ever-increasing data rates pose important computational challenges for data reconstruction and trigger systems, encouraging the exploration of new computing methodologies. In this work we discuss a FPGA-based tracking system, relying on a massively parallel pattern recognition approach, inspired by the processing of visual images by the natural brain (“retina architecture”). This method allows a large efficiency of utilisation of the hardware, low power consumption and very low latencies. Based on this approach, a device has been designed within the LHCb Upgrade-II project, with the goal of performing track reconstruction in the forward acceptance region in real-time during the upcoming Run 4 of the LHC. This innovative device will perform track reconstruction before the event-building, in a short enough time to provide pre-reconstructed tracks (“primitives”) transparently to the processor farm, as if they had been generated directly by the detector. This allows significant savings in higher-level computing resources, enabling handling higher luminosities than otherwise possible. The feasibility of the project is backed up by the results of tests performed on a realistic hardware prototype, that has been opportunistically processing actual LHCb data in parallel with the regular DAQ in the LHC Run 3.
|
|
|
Belle-II DEPFET and PXD Collaborations(Ahlburg, P. et al), & Marinas, C. (2024). The new and complete Belle II DEPFET pixel detector: Commissioning and previous operational experience. Nucl. Instrum. Methods Phys. Res. A, 1068, 169763–6pp.
Abstract: The Belle II experiment at the SuperKEKB collider in Tsukuba, Japan, has collected e+e- + e – collision data between 2019 and 2022. After reaching a record-breaking instantaneous luminosity of 4.71x1034 . 71x10 34 cm -2 s -1 and recording a dataset corresponding to 424 fb -1 , it completed its first planned long shutdown phase in December 2023. Aside from upgrades of the collider and detector maintenance, the shutdown was used for the installation of the two-layer Pixel VerteX Detector (PXD). As the innermost sub-detector, multiple scattering effects need to be reduced. PXD utilizes the Depleted P-channel Field Effect Transistor (DEPFET) technology, allowing for a material budget of 0.21% X0 0 per layer. Each of the tracker's 40 modules consists of an array of 250x768 pixels with a pitch ranging from 50 μmx 55 μm for the inner to 85 μmx 55 μm for the outer layer yielding high gain and high signal-to-noise ratio while retaining about 99% hit efficiency. This article discusses the experience of the 4-year operation of the previous single-layer PXD in harsh background conditions as well as commissioning and testing of the fully-populated PXD2 during Long Shutdown 1.
|
|
|
Babeluk, M. et al, Lacasta, C., Marinas, C., Mazorra de Cos, J., & Vobbilisetti, V. (2024). The OBELIX chip for the Belle II VTX upgrade. Nucl. Instrum. Methods Phys. Res. A, 1067, 169659–3pp.
Abstract: The OBELIX depleted monolithic active CMOS pixel sensor (DMAPS) is currently developed for the upgrade of the vertex detector of the Belle II experiment located at Tsukuba/Japan. The pixel matrix of OBELIX is inherited from the TJ-Monopix2 chip, but the periphery includes additional features to improve performance and allow the integration into a larger detector system. The new features include a trigger unit to process trigger signals, a precision timing module and a possibility to transmit low granularity hit information with low latency to contribute to the Belle II trigger. Additionally, low dropout voltage regulators and an ADC to monitor power consumption and substrate temperature is developed. This paper will focus on the trigger contribution capabilities of the OBELIX chip.
|
|
|
Miyagawa, P. S. et al, Bernabeu, P., Lacasta, C., Solaz, C., & Soldevila, U. (2024). Analysis of the results from Quality Control tests performed on ATLAS18 Strip Sensors during on-going production. Nucl. Instrum. Methods Phys. Res. A, 1064, 169457–9pp.
Abstract: The ATLAS experiment will replace its existing Inner Detector with the new all -silicon Inner Tracker (ITk) to cope with the operating conditions of the forthcoming high -luminosity phase of the LHC (HL-LHC). The outer regions of the ITk will be instrumented with similar to 18000 ATLAS18 strip sensors fabricated by Hamamatsu Photonics K.K. (HPK). With the launch of full-scale sensor production in 2021, the ITk strip sensor community has undertaken quality control (QC) testing of these sensors to ensure compliance with mechanical and electrical specifications agreed with HPK. The testing is conducted at seven QC sites on each of the monthly deliveries of similar to 500 sensors. This contribution will give an overview of the QC procedures and analysis; the tests most likely to determine pass/fail for a sensor are IV, long-term leakage current stability, full strip test and visual inspection. The contribution will then present trends in the results and properties following completion of similar to 60% of production testing. It will also mention challenges overcome through collaborative efforts with HPK during the early phases of production. With less than 5% of sensors rejected by QC testing, the overall production quality has been very good.
|
|
|
Bach, E. et al, Bernabeu, J., Lacasta, C., Solaz, C., & Soldevila, U. (2024). Analysis of the quality assurance results from the initial part of production of the ATLAS18 ITK strip sensors. Nucl. Instrum. Methods Phys. Res. A, 1064, 169435–8pp.
Abstract: The production of strip sensors for the ATLAS Inner Tracker (ITk) started in 2021. Since then, a Quality Assurance (QA) program has been carried out continuously, by using specific test structures, in parallel to the Quality Control (QC) inspection of the sensors. The QA program consists of monitoring sensor-specific characteristics and the technological process variability, before and after the irradiation with gammas, neutrons, and protons. After two years, half of the full production volume has been reached and we present an analysis of the parameters measured as part of the QA process. The main devices used for QA purposes are miniature strip sensors, monitor diodes, and the ATLAS test chip, which contains several test structures. Such devices are tested by several sites across the collaboration depending on the type of samples (non-irradiated components or irradiated with protons, neutrons, or gammas). The parameters extracted from the tests are then uploaded to a database and analyzed by Python scripts. These parameters are mainly examined through histograms and timeevolution plots to obtain parameter distributions, production trends, and meaningful parameter-to-parameter correlations. The purpose of this analysis is to identify possible deviations in the fabrication or the sensor quality, changes in the behavior of the test equipment at different test sites, or possible variability in the irradiation processes. The conclusions extracted from the QA program have allowed test optimization, establishment of control limits for the parameters, and a better understanding of device properties and fabrication trends. In addition, any abnormal results prompt immediate feedback to a vendor.
|
|
|
Belle II VTX Collaboration(Babeluk, M. et al)., Marinas, C., & Mazorra de Cos, J. (2024). The DMAPS upgrade of the Belle II vertex detector. Nucl. Instrum. Methods Phys. Res. A, 1064, 169428–5pp.
Abstract: The Belle II experiment at KEK in Japan considers an upgrade for the vertex detector system in line with the accelerator upgrade for higher luminosity at long shutdown 2 planned for 2028. One proposal for the upgrade of the vertex detector called VTX aims to improve background robustness and reduce occupancy using small and fast pixels. VTX accommodates the OBELIX depleted monolithic active CMOS pixel sensor (DMAPS) on all five proposed layers. OBELIX is specifically developed for the VTX application and based on the TJ-Monopix2 chip initially developed to meet the requirements of the outer layers of the ATLAS inner tracker (ITk). This paper will review recent tests of the TJ-Monopix2 chip as well as various design aspects of the OBELIX-1 chip currently under development.
|
|